Aperture
ND Filter
At default settings, the camcorder’s ND filter is activated automatically depending on the aperture value. The ND 
filter is first activated when you close down the aperture to F4.0 ([ND 1/2] will appear on the screen). As you 
close down the aperture further, the ND filter will change to [ND 1/4] and then to [ND 1/8] for aperture values 
above F4.4.
If you prefer not to use the ND filter, you can turn it off with the following procedure.
1 Open the [ND Filter] submenu.
[~ Camera Setup] > [ND Filter]
2 Select [Off] and then press SET.
Remote Operation Using Browser Remote
After completing the necessary preparations (A 180), you can change 
the ND filter mode remotely from a connected device using the Browser 
Remote application.
1 Press [ND Off] on the Browser Remote screen to turn off the ND 
filter.
2 Press [ND Auto] to return the camcorder to automatic ND filter mode.
Exposure Compensation - AE Shift
Use AE shift to compensate the exposure that was set using automatic aperture, in order to darken or lighten the 
image. You can select from 17 available AE shift levels.
AE shift is not available when the camcorder is set to full auto mode (A 49).
1 Open the [AE Shift] submenu.
[~ Camera Setup] > [AE Shift]
2 Select an AE shift level and then press SET.
• The selected AE shift level will be displayed above the exposure bar 
and the camcorder will attempt to adjust the exposure accordingly.
Available AE Shift Levels
+2.0
+1.75
+1.5
+1.25
+1.0
+0.75
+0.5
+0.25
±
0
-0.25
-0.5
-0.75
-1.0
-1.25
-1.5
-1.75
-2.0
[~ Camera Setup]
[ND Filter]
[Automatic]
[~ Camera Setup]
[AE Shift]
[±0]
The Exposure Bar
When the gain and aperture are both set to manual mode and the shutter speed 
is set to a mode other than auto, the exposure bar will appear, giving you an 
indication of the current exposure. The Î on top of the exposure bar indicates 
optimal exposure without any shift (AE±0) and the indicator inside the exposure 
bar represents the current exposure. 
When the difference between current and optimal exposure is larger than ±2 EV, 
the indicator will flash at the edge of the exposure bar.
Optimal exposure AE±0
Current exposure
COP
Y