Installation
Installation Considerations
22
P1021708-001
TTP 2100 Operator Guide
11/04/2009
Electrostatic Discharges and Earth Currents
Preventing ESD and earth currents from affecting the printer operation requires proper 
connection of the printer chassis to protective earth through a mounting platform or through a 
separate earth conductor. A threaded hole for an M4 earth screw is provided on the back of the 
printer. Use an M4 x 10 screw and two lock washers when fastening the ground cable.
Figure 8 • Location of Earth Grounding Screw
Ambient Light
There is an optical sensor at the paper exit at the front of the printer. 
To ensure proper printer operation, design the kiosk so that it prevents direct sunlight or light 
from indoor lamps from reaching the sensor through the paper exit.
Note • 
An optional antistatic brush can be fitted to the front of the printer if required.
E a rth
S cre w