Adjustments and Settings for Recording: Setting Time Data
Follow the steps below.
1
Turn on the POWER switch.
2
Position the TCG switch at [F-RUN].
3
Position the DISPLAY switch at [TC].
4
Set the menu option GENLOCK to “EXT”.
This option can be found in the <GENLOCK> screen on 
the SYSTEM SETTING page.
5
Supply a phase-relationship reference time code (that 
conforms to the time code requirements) and reference 
video signals to the TC IN and GENLOCK IN 
connectors, respectively.
Now the built-in time code generator is locked with the 
reference time code.
From about 10 seconds after locking the time code 
generator stays locked even if the supply of external 
reference time code is discontinued.
Notes
When the time code generator is externally locked, the 
time code instantly becomes locked with the external time 
code, and the counter displays the external time code 
value. Do not begin recording in the few seconds it takes 
for the synch generator to stabilize.
Be sure to enter the non-drop-frame time code to 
externally lock the time code in the 24P, 24PA or 24PN 
(Native) mode. Externally locking the drop-frame time 
code is not permitted.
Video quality may be degraded momentarily while 
externally locking to adjust the 5-frame cycle. This is not 
abnormal.
While recording data in the 24P, 24PA, or Native modes, it 
is impossible to lock the time code externally. Lock it 
before recording.
Note also that if the unit is used with PRE REC MODE set 
to “ON” in any of the 24P, 24PA or Native modes, 
changing the time code from Rec run to Free run or slave 
locking the time code before recording may result in a 
flickering video or a stopped code being recorded.
In the 1080-23.98PsF mode, the 23.94 Hz non-drop frame 
time code should be supplied. In the 1080-24PsF mode, 
the 24 Hz non-drop frame time code should be supplied.
When the TCG switch is positioned to [F-RUN], only the time 
code is locked to an external time code. To lock the user bits 
to an externally input value, the UB MODE and VITC UB 
MODE menu options must be set to “EXT” and “USER/EXT”, 
respectively.
The menu option UB MODE and VITC UB MODE can be 
found in the <TC/UB> screen on the MAIN OPERATION 
page.
Discontinue external time code supply, then position the 
TCG switch at [R-RUN].
Connect the DC IN socket with the external power supply 
before removing the battery pack, in order to keep the time 
code generator energized. If the battery pack is removed 
first, there is no guarantee that the time code will stay 
externally locked.
When the time code is externally locked, the reference video 
signals input through the GENLOCK IN connector gen-lock 
the camera.
Notes
To externally lock the unit, as the master device, with more 
than one unit, the mode must be the same as that of the 
camera. Note that in a system using both interlaced and 
progressive scanning, there may be breaks in the video 
and time code.
When using the MON OUT connector to output reference 
signals, position the OUTPUT SEL switch on the side 
panel at [CAM].
To display the time code in the viewfinder or the LCD monitor 
when recording or during playback, set TC in <VF 
INDICATOR3> to “TCG”, “TCR”, or “TCG/TCR”.
To include the time code indication in the MON OUT or HD 
SDI A · B outputs, set the MON OUT CHARACTER switch to 
[ON], and set HD SDI A · B CHAR to “ON” from the 
<OUTPUT SEL> screen using the menu.
To display the time code while the color bar is displayed, set 
TC ON COLOR BAR in <VF INDICATOR3> to “ON”.
To externally lock the time code
Setting the user bits when the time code is 
externally locked
To unlock the externally locked time code
Cautions in switching the power source from 
battery to external power supply
External synchronization of the camera when the 
time code is externally locked