Enterasys Networks X009-U 사용자 설명서

다운로드
페이지 86
Installing and Removing a Power Supply
3-12 Matrix X4-C Chassis Setup
Power Supply Planning
Although each power supply requires its own circuit, when planning the X4‐C power budget you 
have the option of drawing from one or more sources by either the N + 1 or 1 + 1 method, 
respectively.
Drawing power by the N + 1 method protects the X4‐C against the failure of a single power source 
although not against an outage by that source. In a scheme where three modules are installed, as 
shown in 
, you can assign all three modules to source “A.” This is the most common 
approach to power supply planning.
Figure 3-10  Power Supply Planning: N + 1 Method
Alternately, drawing power by the 1 + 1 method has the advantage of protecting the X4‐C against 
an outage by one of the power sources as well as the failure of one or as many as half of your 
power supplies. However, this method requires either a backup battery or another power source 
separate from the first power source. As shown in 
, three power supplies are installed 
with two assigned to source “A” and the other to source “B.” 
Figure 3-11  Power Supply Planning: 1 + 1 Method
Installing a Power Supply
Power supplies are installed in slots located at the base of the chassis, as shown in 
. If 
you intend to install only a single power supply, it can be installed in any of the slots labeled PS1 
to PS3 in the chassis although the PS1 slot is left open for your convenience.
To install power supplies in the Matrix X4‐C chassis, refer to the following figures and proceed as 
follows:
1.
Unpack the power supply by removing it from its shipping box and stripping the packing 
material. (Save the shipping box and materials in the event the unit must be reshipped.)
2.
Remove the power supply from its protective wrapping.
3.
Examine the power supply carefully, checking for damage. If any damage is noted, do not 
install the power supply. Contact Enterasys Networks for instructions.
4.
Locate the ESD wrist strap shipped with the Matrix X4‐C chassis. Attach the ESD wrist strap 
to your wrist and plug the cable from the ESD wrist strap into the ESD grounding receptacle 
at the bottom of the chassis as shown in 
.
5.
Remove the vent plate covering all power supply slots by loosening the side captive screws, as 
shown in 
.
N
+
1
Source A
3
2
1
3
2
1
1
+
1
Source A
Source B