Sony DXC-D30WS 사용자 설명서

다운로드
페이지 90
3-9
DXC-D30WS/P(E)/V1
3-3-11. CCD Output Level Adjustment
Note :
• Use a reflection type with chart for this
adjustment, therefore, control the light so
that the white area of chart is exactly 3200K
of color temperature.
• If use the pattern box, make sure that the
color temperature must be 3200K.
• Usually, this adjustment is not required.
Only when the output level of CCD unit is
large different from the specification.
• When the new CCD unit of spare parts is
replaced, this adjustment is not required
because of the correct adjustment at the
factory.
Object:
Grayscale chart
Equipment:
Oscilloscope
To be extended: VA-185 board
Preparation:
• OUTPUT/DL/DCC
+ switch/camera side
 CAM/DCC
+
• WHITE BAL switch/camera side
 PRESET
• Chart frame = Underscanned monitor frame
• Adjust the lens iris so that the video level at TP27/
extension board (VA-185 board) is 165 
±
5 mV.
Trigger:
HD (TP72/extension board)
Adjustment Procedure
1. Test point: TP15/extension board (VA-185 board)
1RV1/PA-219 (B) board
Specification : A = 165 
±
5 mV
2. Test point: TP21/extension board (VA-185 board)
1RV1/PA-221 (R) board
Specification : A = 165 
±
5 mV
3-3-10. VF SYNC/BLKG Level Adjustment
Equipment:
Oscilloscope
To be extended: ES-22 board
Preparation:
OUTPUT/DL/DCC
+ switch/camera side
       →
 BARS
Trigger:
HD (TP84/extension board)
Adjustment Procedure
1. SERVICE menu “PAGE 7”
VF SYNC
VF BLKG
Note:
For the adjustment procedure, at the first “VF
BLKG” adjustment is done, and next, “VF
SYNC” adjustment is done.
2. Adjust the following items by UP 4 switch or DOWN
$ switch.
Extension board (GND : TP81/ES-22 board)
Item
Test Point
Specification
VF BLKG
TP82
NTSC : A = 50 
±
10 mV
PAL
: A = 50 
±
10 mV
VF SYNC
TP82
NTSC : B = 286 
±
10 mV
PAL
: B = 300 
±
10 mV
[for NTSC]
[for PAL]
B
A
B
A
RV1
CN2
CN3
PA-219 (B) BOARD
PA-221 (R) BOARD
- A SIDE -
- A SIDE -