Hitachi vl-21a 사용자 설명서
3. Measurement
Specifications
See “Appendix 2” for Standard Measurement Condition and
Measurement
Procedure
4. Environment Condition and Test
Operating Condition
Temperature -10°C ~ 60°C
(Recommendation:
-5°C
~
50°C)
Humidity 20% ~ 60%
Storage Condition
Temperature -40°C ~ 60°C
Humidity 0% ~ 90%
4.1 High Temperature Storage Test
In Storage condition at a temperature of 60°C for 72 hours, t
hen leaving it at Normal Temperature for 8 hours, there will be
no problem in performance.
4.2 Low Temperature Storage Test
In Storage condition at a temperature of -40°C for 72 hours,
then leaving it at Normal Temperature for 8 hours, there will be
no problem in performance.
5. Interface
5.1 Pin Assignment
TTL Communication (10 Pin FFC Connector; Maker LinkWork
1.0mm Pitch, Upper Contact)
5.2 J204 - 10 Pin Connector
5.3 Line In Pulse
(Ex,
(Ex,
FV)
* The 10 pin Connector (JAE) over the camera module is used
for manufacturing. (Not for user)
Pin Name
I / O
Level
1
C Out
Output
Chroma Out
2
Y Out
Output
Luminance Out
3
Gnd
Video Ground
4
V Out
Output
Composite Video Output
5
12 V
Input
11.5 to 12.5 volts DC
6
Key 1
Input
7
Key 2
Input
8
RXD
Output
CMOS Level 5v (low:
≤ 0.8v, High: ≥ 3.7v
9
TXD
Input
CMOS Level 5v (low:
≤ 0.8v, High: ≥ 3.7v
10
Gnd
Power / Data Ground
200nsec min
60 Hz ±0.25Hz
5v
0v
0v
5