Replace consumable products
• The O-ring is a consumable product. Independent of the number of times the Case is used, it is 
recommended that the O-ring should be replaced by a new piece at least once a year.
• Deterioration of the O-ring is accelerated by the usage conditions and the storage conditions. Replace 
the O-ring even before a year has passed if it shows signs of damage, cracking or loss of elasticity.
Maintenance of the threaded sections on the TTL cable and TTL 
cable connector
If the threaded sections used to connect the TTL cable to the TTL cable connector are not maintained 
properly, salt and other seawater residue may adhere to the TTL cable and prevent it from being 
disconnected.
After use in seawater, clean off any salt, sand, or other residue as soon as possible, then dry the 
equipment thoroughly. Clean the threaded sections with a cotton swab and apply a thin, uniform layer of 
silicone grease (provided with this case).
Maintenance of the TTL Connector Cap
After removing the TTL connector cap from the Underwater Case, be sure to clean and grease the O-
ring.
Use the maintenance adapter to remove the O-ring unit from the TTL connector cap.
* Reverse the removal procedure to re-attach the O-ring unit to the TTL connector cap.
CAUTION:
• Please use genuine Olympus silicone grease, silica gel and O-ring.
• Do not try to replace the O-ring by yourself.
• We recommend to perform the check periodically.
1
Insert the adapter by aligning its pin with the hole on 
the cap.
2
Turn the adapter counterclockwise to remove the O-
ring unit.
3
After removing the O-ring attached to the O-ring unit, 
clean the O-ring groove and apply silicone grease to 
the O-ring. Then, re-attach the O-ring to the O-ring 
unit.
Clean and apply silicone grease to these 
sections.
Maintenance adapter
TTL connector cap
O-ring