WITE32 Release Notes Version 3.11 
 
 
There are two frames in the dialog box – the Erase Parameters frame and the Band Erase Parameters frame.  
The Erase Parameters frame allows you to define the erase configuration. 
The Iterations text box 
Defines the number of repetitions for each erase operation at each 
offset 
The Mode option buttons 
Defines the erase modes: 
•  Positive DC – the DC erase operation using the positive write 
current for one revolution. 
•  Negative DC – the DC erase operation using the negative 
write current for one revolution. 
•  Positive DC / Negative DC – the DC erase operation using 
the positive write current for the first revolution, followed by 
the DC erase operation using the negative write current for 
the second revolution. 
•  Negative DC / Positive DC – the DC erase operation using 
the negative write current for the first revolution, followed by 
the DC erase operation using the positive write current for 
the second revolution. 
•  AC – the AC erase operation for one revolution with the 
frequency defined in the Frequency text box. 
The Frequency text box 
Defines the frequency for the AC erase operation, in MFlux/s. 
The Write Current text boxes  Define the write current values (in mA) used in the erase operation. 
You can configure individual write current for the first and the second 
revolution.  
The Use System check boxes 
If the check box is checked, the Write Current text box value for the 
corresponding revolution is ignored.  The current system write current 
is used instead. 
The Band Erase Parameters frame allows you to define the area around the current track for the band erase operation. 
The From text box 
Defines the starting offset position for the band erase operation, 
in 
µInch.   
The To text box 
Defines the ending offset position for the band erase operation, 
in 
µInch. 
The Step text box 
Defines the offset step size for each erase operation, in 
µInch. 
The Interleave Band Erase 
check box 
If it is checked, the Mode option is ignored.  The band erase operation 
is done in the following way: 
1.  Erase using the positive write current at the first offset 
position. 
2.  Erase using the negative write current at the second 
offset position. 
3.  Erase using the positive write current at the third offset 
position, etc.  
Note:  
The band erase area is specified in terms of the head writer offset (in 
µInch) in respect to the center of the track. 
All  System Erase and  System Band Erase parameters are zone/setup dependent, you can double-click on the 
parameter label to specify the value of the parameter for each zone and setup. 
 
 
 
 