EGPWS LINE MAINTENANCE MANUAL 
CAGE CODE: 97896 
SCALE: NONE     SIZE: A 
DWG NO.:  060-4199-180 
REV:   G 
SHEET  13 of 68 
 
MODEL
CALLOUT DESCRIPTION 
V VI VII VIII
XXII 
500 TONE 
Provides 2 second 960 Hz tone at descent below 500 
feet 
•  # 
• 
# # 
SMART “FIVE HUNDRED” 
At descent below 500 feet (only) during non-precision 
approach  
•  • 
• 
• 
• 
“FIVE HUNDRED” 
Above field callout within 5 nm of a runway in the 
database 
• 
• 
“FIVE HUNDRED ABOVE” 
Above field callout within 5 nm of a runway in the 
database 
• 
• 
“FOUR HUNDRED” 
At descent below  400 feet  
•  • 
• 
• 
“THREE HUNDRED” 
At descent below 300 feet 
•  • 
• 
• 
“TWO HUNDRED” 
At descent below 200 feet 
•  • 
• 
• 
• 
“ONE HUNDRED SIXTY” 
At descent below 160 feet 
# #  #  # 
• 
“ONE HUNDRED FIFTY” 
At descent below 150 feet 
# #  #  # 
• 
“ONE HUNDRED FORTY” 
At descent below 140 feet 
# #  #  # 
• 
“ONE HUNDRED THIRTY” 
At descent below 130 feet 
# #  #  # 
• 
“ONE HUNDRED TWENTY” 
At descent below 120 feet 
# #  #  # 
• 
“ONE HUNDRED TEN” 
At descent below 110 feet 
# #  #  # 
• 
“ONE HUNDRED” 
At descent below 100 feet 
•  • 
• 
• 
• 
100 TONE 
Provides 2 second 700 Hz tone at descent below 100 
feet 
•  # 
• 
# # 
“EIGHTY” 
At descent below 80 feet 
•  # 
• 
• 
“SIXTY” 
At descent below 60 feet  
•  # 
• 
• 
“FIFTY” 
At descent below 50 feet  
•  • 
• 
• 
• 
“FOURTY” 
At descent below 40 feet  
•  • 
• 
• 
• 
“THIRTY FIVE” 
At descent below 35 feet 
•  # 
• 
# # 
35 TONE 
Provides 1 second 1400 Hz tone at descent below 35 
feet 
•  # 
• 
# # 
“THIRTY” 
At descent below 30 feet  
•  • 
• 
• 
• 
“TWENTY” 
At descent below 20 feet  
•  • 
• 
• 
• 
20 TONE 
Provides 1/2 second 2800 Hz tone at descent below 
20 feet 
•  # 
• 
# # 
“FIFTEEN” 
At descent below 15 feet 
•  # 
• 
# # 
“TEN“ 
At descent below 10 feet  
•  • 
• 
• 
• 
“FIVE”  
At descent below 5 feet  
•  # 
• 
# # 
# Not currently identified in any menu option for the model indicated.