Honeywell MK VI 사용자 설명서
EGPWS LINE MAINTENANCE MANUAL
CAGE CODE: 97896
SCALE: NONE SIZE: A
DWG NO.: 060-4199-180
REV: G
SHEET 13 of 68
MODEL
CALLOUT DESCRIPTION
V VI VII VIII
XXII
500 TONE
Provides 2 second 960 Hz tone at descent below 500
feet
feet
• #
•
# #
SMART “FIVE HUNDRED”
At descent below 500 feet (only) during non-precision
approach
approach
• •
•
•
•
“FIVE HUNDRED”
Above field callout within 5 nm of a runway in the
database
database
#
•
#
•
#
“FIVE HUNDRED ABOVE”
Above field callout within 5 nm of a runway in the
database
database
#
•
#
•
#
“FOUR HUNDRED”
At descent below 400 feet
• •
•
•
#
“THREE HUNDRED”
At descent below 300 feet
• •
•
•
#
“TWO HUNDRED”
At descent below 200 feet
• •
•
•
•
“ONE HUNDRED SIXTY”
At descent below 160 feet
# # # #
•
“ONE HUNDRED FIFTY”
At descent below 150 feet
# # # #
•
“ONE HUNDRED FORTY”
At descent below 140 feet
# # # #
•
“ONE HUNDRED THIRTY”
At descent below 130 feet
# # # #
•
“ONE HUNDRED TWENTY”
At descent below 120 feet
# # # #
•
“ONE HUNDRED TEN”
At descent below 110 feet
# # # #
•
“ONE HUNDRED”
At descent below 100 feet
• •
•
•
•
100 TONE
Provides 2 second 700 Hz tone at descent below 100
feet
feet
• #
•
# #
“EIGHTY”
At descent below 80 feet
• #
•
#
•
“SIXTY”
At descent below 60 feet
• #
•
#
•
“FIFTY”
At descent below 50 feet
• •
•
•
•
“FOURTY”
At descent below 40 feet
• •
•
•
•
“THIRTY FIVE”
At descent below 35 feet
• #
•
# #
35 TONE
Provides 1 second 1400 Hz tone at descent below 35
feet
feet
• #
•
# #
“THIRTY”
At descent below 30 feet
• •
•
•
•
“TWENTY”
At descent below 20 feet
• •
•
•
•
20 TONE
Provides 1/2 second 2800 Hz tone at descent below
20 feet
20 feet
• #
•
# #
“FIFTEEN”
At descent below 15 feet
• #
•
# #
“TEN“
At descent below 10 feet
• •
•
•
•
“FIVE”
At descent below 5 feet
• #
•
# #
# Not currently identified in any menu option for the model indicated.