ICOM IC-706MKIIG 사용자 설명서

다운로드
페이지 75
47
7
SET MODE
■ General
Set mode is used for programming infrequently
changed values or conditions of functions. The IC-
706MKIIG has 2 separate set modes: 
quick set mode
and 
initial set mode.
Quick set mode operation
While power is ON, push [DISPLAY] for 2 sec.
• Quick set mode is selected and one of its items appears.
• Quick set mode items vary depending on the operating
mode (SSB, FM, etc.) selected.
Push [MENU] one or more times to select the
desired item.
• [M-CH] or [Y]/[Z] can also be used.
Rotate the main dial to set the values or conditions
for the selected item.
Repeat steps 
➁ and ➂ to set other items.
To exit quick set mode, push [DISPLAY] momentar-
ily.
Initial set mode operation
Push [POWER] for 2 sec. to turn power OFF.
While pushing [LOCK] push [POWER] to turn power
ON.
• Initial set mode is selected and one of its items appears.
Push [MENU] one or more times to select the
desired item.
• [M-CH] or [Y]/[Z] can also be used.
Rotate the main dial to set the values or conditions
for the selected item.
Repeat steps 
➂ and ➃ to set other items.
To exit initial set mode, push [POWER] for 2 sec. to
turn power OFF.
Push [POWER] to turn power ON again.
• The conditions selected in initial set mode are now effec-
tive.
[POWER]
[MENU]
[LOCK]
Main dial
Item number
Item
Value or 
condition
 1 MODE SELECT
[DISPLAY EXAMPLE: INITIAL SET MODE]
[M-CH]
[Y]
[Z]
Q1
RF POWER
USB
[POWER]
[MENU]
[M-CH]
[DISPLAY]
Main dial
[Y]
[Z]
Item number
Item
Value or 
condition
[DISPLAY EXAMPLE: QUICK SET MODE]
P
O
S1
5
5
3
7
9
20
40
10
60dB