GE 4 Series 사용자 설명서

다운로드
페이지 72
Concord  4 Series Security Systems
9
Auto STAY Arming Feature
The Auto STAY Arming feature helps cut down on false alarms in the event that you arm the 
system to 3—AWAY, but fail to leave during the Exit Delay time. Here’s how it works:
Exit Extension Arming Feature
The exit extension arming feature helps cut down on false alarms in the event that you arm the 
system and exit the premises, but re-enter before the exit delay expires.
Note  
If the exit extension arming feature is on, the exit delay will be restarted only once.
Arming Your System Silently
Note  
If Quick Arm feature is on, 
an access code is not 
required. See “Quick Arm” 
for more information.
Use the Silent arming feature to arm your system without disturbing people throughout the house 
with arming status beeps. Pressing
 5—Silent 
before arming silences arming status and exit 
beeps from touchpads and interior sirens, only for the current arming period.
To arm your system silently:
Note  
 
Exit Delay is doubled when 
arming silently.
1. From any touchpad, press 
5
.
2. Within 4 seconds enter: 
2
 + 
CODE
 or
 
3
 + 
CODE
.
Bypassing—Arming With a Door or Window Open
Note  
Smoke/heat sensors cannot 
be bypassed.
It is possible to arm your system while leaving a door or window open. This is useful if, for 
example, you like to sleep at night with a window open.
If the door or window has a sensor installed on it, the system must be told to ignore or bypass that 
sensor when it’s open. All other sensors remain active.
There are two methods for bypassing a sensor:
Note  
When a sensor is bypassed, 
you are allowing that door or 
window to be unprotected.
• Directly — After arming the system, bypass door/window sensors before you open them. 
You must know the sensor number of the door or window you wish to bypass. Your installer 
can include the zone number as part of the sensor text.
• Indirectly — As you are arming, bypass sensors on doors and windows that are already 
open. This method should not be used in UL Listed installations.
Bypassing a Sensor Directly
Use this method if the system is armed and you would like to open a window without disarming.
Refer to the “Appendix A: User Sheets” to determine the sensor number you wish to bypass.
Note  
You cannot bypass sensors 
directly using a keychain 
touchpad.
To bypass sensors directly:
1. Close all doors and windows.
2. Arm your system to the desired level.
If you arm the system to Level 3—AWAY, and do not leave the premises within the Exit Delay time
With feature turned on
The system detects that no one opened and closed a delay door 
within the delay time. It assumes that someone is still inside and 
arms to 2—STAY to prevent a false alarm.
If feature turned off
The system arms to Level 3—AWAY regardless of whether or not 
a delay door has been opened and closed.  
Your movement inside the premises could activate a motion 
detector, causing an alarm.
If you arm the system, leave the premises, and then re-enter within the exit delay time:
With feature turned on
The system detects that a delay door opened twice within the delay 
time. It assumes you re-entered the premises, so it restarts the exit 
delay, giving you additional time to exit again.
If feature turned off
The exit delay continues to count down. Even if a delay door is 
opened a second time.
Your movement inside the premises could activate a motion 
detector, causing an alarm.