GE 4 Series 사용자 설명서

다운로드
페이지 72
Concord  4 Series Security Systems
50
Alarm Sounds and Status Beeps
Alarm Type
Alarm Sound
Fire
Repeating series of three beeps.
Police
Continuous tone.
Auxiliary
Rapid Beeps.
Beep Type
Beep Sound
Exit Delay
2 or 3 beeps (indicating arming level), followed by 1 beep every 4 seconds, 
followed by 10 seconds of quick beeps (indicating end of exit delay), followed by 
2 or 3 beeps (indicating set arming level).
Entry Delay
2 beeps every 2 seconds, followed by 2 beeps every second for the last 10 seconds.
Chime
2 beeps whenever a protected door or window is opened.
Chime on Close 1 long beep when a protected door or window is closed.
Protest
Repeating pattern of 1 long beep, followed by 1 short beep, followed by 1 long 
beep.
Trouble
5 short beeps once every minute.
Sensor Test
1 short, high-pitched beep when a sensor/touchpad tests OK.
1 short, low-pitched beep when a sensor/touchpad fails a test. Contact your dealer 
for information or service.
1 short beep every minute during the last 5 minutes of sensor test.