DMP Electronics XR500 사용자 설명서

다운로드
페이지 84
Digital Monitoring Products 
XR500 Series Canadian Programming Guide
30
SySTem oPTionS
For example, when Spanish is selected at a keypad, the User Menu and Status List
text display in Spanish at 
that keypad. When the user later accesses the keypad,
pressing the COMMAND key once displays the option for English, Spanish, or French.
Pressing the COMMAND key again continues to display the Status List text in Spanish.
Later on, if English or French is selected at
that keypad, the User Menu and Status 
List text display in the selected language at
that keypad.   
NONE  ENG  SPN  FRN
 
Select the secondary user language. 
NONE = No secondary language options are displayed 
ENG = English (ENGLISH) 
SPN = Spanish (ESPANOL) 
FRN = French (FRANCAIS)
9.15 
BYPASS LIMIT  
0
 Bypass Limit
Enter the maximum number of zones (0 to 8) that can be bypassed in any single area
when that area is being armed at a keypad.  If more zones than the limit are in a 
non-normal state or already bypassed at arming, arming does not occur and Arming
Stopped displays.  The Bypass limit does not affect auto arming or keyswitch arming.  
Entering 0 (zero) allows no limit. Default is 0 (zero).
9.16 
 
CARD PLUS PIN:
 
  NO YES
 Card Plus PIN (XR500E only)
Select YES to require all users to present a proximity credential and enter a PIN 
number wherever user code entry is required for system functions accessed from a 
keypad. Select NO to disable Card Plus PIN operation. Default is NO.
Note: The Card Plus PIN option is not designed to operate with All/Perimeter or
Home/Sleep/Away systems.
For an XR500E system using Card Plus PIN, two code entries are required by a user to 
operate the system from a keypad. The first must be a code entered from a Wiegand
interface device (card, fob, etc.) using a reader such as the built-in reader of a DMP
Keypad. An external reader may also be used. The second code (User Pin) is keyed
in at the keypad or could be a second card or fob.
For a Card Plus PIN system, user codes (Card and PIN) are typically administered
using DMP System Link software.
When this option is first turned on at a keypad, the factory default (user number
9999, user code 99) must be available to enter the user menu at a keypad to then
add user codes and PIN numbers or to change existing users to add their PIN number. 
If user 9999 was previously removed, re-enter this user and then set Card Plus
Pin = YES. Afterwards, user 9999 can be removed and the system only allows card
plus PIN entries.
Note: Current users of an existing system are immediately affected in that they must 
have their user code information changed to add the user PIN.
9.17 
 
WIRELESS
HOUSE CODE: 0
 House Code
When using a DMP wireless system, enter a house code between 1 and 50. When
using FA Series wireless enter 99. See Wireless programming in Zone Information.
Default is 0 indicating no wireless system is being used.  
The DMP house code identifies the panel, DMP receiver, and DMP transmitters to
each other. When operating, the DMP receiver listens for transmissions that have
the programmed house code and transmitter serial number.  
Note: The flexibility of DMP two-way wireless operation allows an existing house
code to be changed in the panel at any time.  The transmitters may take up to two 
minutes to learn the new house code and continue operation. 
Note: When any wireless zone programming is changed in the panel, wireless
receiver zone programming is updated.  At that point, all wireless zones display as 
normal for approximately 1 minute, regardless of the actual state of the zone.
9.18 
 
DETECT WIRELESS
JAMMING:  NO YES
 Detect Wireless Jamming
This option displays when the House Code entered is for a DMP 1100 Series Wireless
system (1-50). When enabled and the wireless receiver detects jamming, a trouble
or alarm message displays in the Status List and is sent to the central station
receiver. Select YES to enable jamming messages to display in the Status List.
Select NO to disable jamming messages. Default is NO.