45
area informaTion 
18.5 
CLS CHK 
NO  YES
 Closing Check
Select YES to enable the panel to verify that all areas in the system are armed 
after permanent or extended sched ules ex pire. If the Clos ing Check finds any areas
disarmed past the sched uled time, the keypads selected to display System Trouble 
Status displays CLOSING TIME!
 and emits a steady beep. When Area Schedules is set
to YES in Area Information, the specific area and name display followed by — LATE.
When Auto Arm is NO, if within ten minutes the system is not armed or if the
schedule is not extended, a Late to Close report is sent to the SCS-1R Receiver.
When Auto Arm is YES, the area arms. See Automatic Arming section.
If the area becomes disarmed outside of any schedule, the Closing Check sequence 
occurs after the Late Arm Delay time. See Late Arm Delay.
When Closing Check is NO and Auto Arm is YES, the system immediately arms when
the schedule expires.  No warning tone occurs.  
In addition, when Closing Check is NO, the option to extend a schedule does not
display when the schedule expires.   
18.6 
CLS CODE  NO  YES
 Closing Code
When YES is selected, a code number is required for system arming. If NO is
selected, a code number is not required for system arming.
18.7 
ANY BYPS  NO  YES
 Any Bypass
When YES is selected, zones can be bypassed without a code number during the
arming sequence. A code number is always required to use the Bypass Zones option
from the menu.
18.8 
AREA SCH  NO  YES
 Area Schedules
Select 
YES to allow each area to set its own shift schedules 1 to 4.  Enter NO to 
provide one set of schedules for this system.
Note: Area Schedules are not designed to operate with All/Perimeter or Home/
Sleep/Away systems.
18.9 
EARLY AMBUSH:   0
 Early Morning Ambush (XR500N/XR500E only) 
Enter the number of minutes (1 to 15) before a silent alarm (Early Morning Ambush S33)
is sent to the central station using the area 1 account number. Enter 0 (zero) to disable
this option.
When a user code is entered to disarm area 1 at a keypad or reader with Access
Areas assigned to area 1, the same or different user code must be entered within the 
programmed number of minutes to prevent an ambush message from being sent to 
the receiver.  The second user code also must have authority to disarm area 1.
In addition, a zone activation with Alarm Action Message C also cancels the Early 
Morning Ambush timer and stops an Ambush message from being sent to the receiver.  
See Report to Transmit section in Zone Information.
The keypad does not display any indication that the ambush timer is running.
Indications can be provided by assigning an output number to Entry Out and Ambush
Out in Output Options. Entry Out turns on one minute before the timer expires and
turns off at expiration. Ambush Out turns on at the timers’ expiration and turns off
when Sensor reset is performed.
18.10 
AREA NO: -
 Area Number
Enter the number of the area to program.  After entering the area number, press 
COMMAND to enter the area name. Only Area systems allow the area name to be
changed.
Note: When All/Perimeter or Home/Sleep/Away is selected as the system type, the
Area Number does not display.
18.10.1  
All/Perimeter Programming
When All/Perimeter is selected as the system type, program the Interior and
Perimeter areas as needed.
 
INT 
 