Pelco es3012 사용자 설명서

다운로드
페이지 40
14
Pelco Manual C306M-K (4/05)
OPERATION
POWER-UP DISPLAY
When the Esprit system is powered up or reset, the selected protocol, revision number, and
other information is displayed on the monitor. For example, the screen might show the fol-
lowing information:
The information displayed depends on the selected protocol
(C, D, or P) and the menu selection for power-up mode.
(Refer to the 
Power-Up Mode in the Programming
 section).
The information remains on the monitor until the dome is
moved.
HOW TO OPERATE YOUR ESPRIT INTEGRATED POSITIONING
SYSTEM
Operation
How to Control
Pan and Tilt
Move joystick left/right and up/down.
Scanning
Stop Scan
Call preset 96.
Random Scan
Call preset 97.
Frame Scan
Call preset 98.
Auto Scan
Call preset 99.
Presets
Refer to the documentation supplied with the controller.
Patterns
Refer to the documentation supplied with the controller.
Zones
Refer to the 
Programming
 section and to the
documentation supplied with the controller.
For more information refer to 
Operating Notes
.
OPERATING NOTES
ENVIRONMENTAL RANGE
The operating temperature ranges from a minimum of -40°F (-40°C) to a maximum of 122°F
(50°C) for sustained system operation or 140°F (60°C) absolute maximum. The entire unit
can de-ice and be operational in two hours from a temperature of -13°F (-25°C). The thermo-
statically controlled heater consumes 10 watts and cycles on at 70°F (21°C) and off at 85°F
(29°C), while the window defroster runs continuously and consumes 2.5 watts.
PAN AND TILT FUNCTIONS
Controller
Pan
Tilt
Type
(Capability, 360° Continuous
(Viewing Range, +40° to -90°)***
Pan Rotation)**
Fixed speed
Speed determined by
Speed determined by controller
controller
*Variable speed
0.5 to 40° per second,
0.5 to 20° per second, depending
depending on joystick position
on joystick position
*Turbo Mode
100° per second
Does not affect the tilt speed
*Preset Mode
100° per second
30° per second
*50 mph wind speed profile.
** If manual limit stops are set, “Pan Limit” appears on your monitor when a limit stop is
reached. This does not apply to scan limit stops.
*** When the system reaches the upper limit, “Tilt Limit” appears on your monitor.
PELCO ESPRIT 1.20
CONFIGURE DONE
D Address 1
P Address 2