APPENDIX
NOTE:
 Esprit will sense and automatically select input from Coaxitron
 
control signals in
either the standard or extended mode. Therefore, the DIP switches settings have no
effect on Coaxitron control signals.
Table A.  Switch Settings for SW1
Baud Rate
Switch Setting
SW1-1
SW1-2
SW1-3
2400
OFF
OFF
OFF*
4800
ON
OFF
OFF*
9600
OFF
ON
OFF*
* SW1-3 is not used; set it in the OFF position.
Switch Setting
SW1-4
SW1-5
SW1-6
SW1-7
SW1-8
OFF*
Note (1)
Note (2)
Note (3)
Note (4)
NOTES:
(1)
SW1-5
OFF - For controllers that have more than 32 presets.
ON
- For American Dynamics controllers (32 presets).
(2)
SW1-6
OFF - For all control systems except CM9502 with variable
speed keyboards. For CM9502 with fixed speed keyboards,
set switch OFF.
ON
- For CM9502 with variable speed keyboards to get
smoother joystick control.
(3)
SW1-7
OFF - RS-422 transmitter is not terminated.
ON
- RS-422 transmitter is terminated.
(4)
SW1-8
OFF - RS-422 receiver is not terminated.
ON
- RS-422 receiver is terminated.