Communication Manager Maintenance-Object Repair Procedures
2402 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1005
ABRT
Wrong circuit pack configuration to run this test. This error applies only to 
DS1 Interface circuit packs. It means the DS1 Interface circuit pack is 
providing timing for the system, and therefore, it cannot be reset without 
major system disruptions.
1. If the circuit pack needs to be reset, then set synchronization to 
another DS1 Interface circuit pack or to the IPSI or Tone-Clock circuit 
pack and try again. See 
1015
ABRT
Port is not out-of-service.
1. Busyout the circuit pack.
2. Execute reset board location again.
2100
ABRT
System resources required for this test are not available.
1. Retry the reset board location at 1-minute intervals up to 5 
times.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
1. Execute reset board location again.
2. If the problem persists, replace the circuit pack.
PASS
The circuit pack initializes correctly.
1. Run the short test sequence.
Table 856: Test #53 SAKI Sanity Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3