ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 1 June 2005
363
 
ADX16A-PT (AUDIX Analog Line/Control Link)
S8700 | 8710
 
S8500
!
CAUTION:
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow the 
instructions on the TN566/TN2169 faceplate:
Remove EMBEDDED AUDIX circuit packs
Cycle power to a carrier containing EMBEDDED AUDIX circuit packs
Remove power to a carrier containing EMBEDDED AUDIX circuit packs
The ADX16A-PT MO represents a port on a TN566/TN2169 EMBEDDED AUDIX circuit pack 
that is operating in control-link (CL) mode. For circuit-pack-level problems (ADX16A-BD or 
ANL-16-BD), see 
port-level problems with AUDIX operating in digital-port mode, see:
The tests described in this section apply only to switch-side maintenance that tests a circuit 
pack’s components related to the TDM-bus interface. The AUDIX system has an extensive 
maintenance strategy that is described in DEFINITY AUDIX System Release 3.2.4 
Maintenance, 585-300-110
.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction board (MFB) and 
the TN2169 Alarm board (ALB). Because of its size this combination occupies 5 slots, but only 1 
slot is functional as far as the switch is concerned. The other 4 slots are seen by the switch as 
“AUDIX-reserved” slots.
In CL mode the TN566 pack supports up to 16 voice ports. When a call to a station with an 
AUDIX login is not answered, AUDIX answers the call using one of the available voice ports.
Unlike other AUDIX systems, EMBEDDED AUDIX is not an adjunct.
MO Name in 
Alarm Log
Alarm 
Level
Initial Command to Run
Full Name of MO
ADXCL-PT 
or ADX16A-P
MIN
test port location l
AUDIX Analog Line/ Control Link
ADXCL-PT 
or ADX16A-P
WRN
test port location sh
AUDIX Analog Line/ Control Link