Lennox International Inc. T-CLASS TM SEPARATED COMBUSTION UNIT HEATERS 사용자 설명서

다운로드
페이지 21
 
Page 15 
Gas Valve Operation for White Rodgers 36E Series 
Valve (Figure 12) 
1-  STOP! Read the safety information at the beginning 
of this section. 
2-  Set thermostat to lowest setting. 
3-  Turn off all electrical power to appliance. 
4-  This appliance is equipped with an ignition device 
which automatically lights burner. DO NOT attempt 
to light the burners manually. 
    
 
FIGURE 12 
WHITE RODGERS 36E GAS VALVE
GAS VALVE KNOB 
 
SHOWN IN OFF POSITION
 
NO
 
OFF
 
MANIFOLD PRESSURE
ADJUSTMENT SCREW
MANI-
FOLD 
PRESSURE 
TAP
INLET 
PRESSURE 
TAP
 
 
5-  Turn knob on gas valve 180° either way to OFF.    
6-  Wait five minutes to clear out any gas. If you then 
smell gas, STOP! Immediately call your gas 
supplier from a neighbor's phone. Follow the gas 
supplier's instructions. If you do not smell gas go to 
next step.  
7-  Turn knob on gas valve 180° either way to ON
8-  Close unit door. 
9-  Turn on electrical power to unit. 
10- Set thermostat to desired setting. 
11-  The combustion air blower will start. The burners 
will light within 40 seconds. 
12- 
If unit does not light first time (gas line not fully 
purged) it will attempt up to two more ignitions 
before locking out. 
13- If lockout occurs, repeat steps 1 through 10. 
14- 
If appliance still will not operate, follow the 
instructions “To Turn Off Gas to Unit" and call 
your service technician or gas supplier. 
Gas Valve Operation for Robertshaw 2000DER 
Series Valve (Figure 13) 
1- STOP! Read the safety information at the beginning 
of this section. 
2-  Set the thermostat to lowest setting. 
3- Turn off all electrical power to appliance. 
4- This appliance is equipped with an ignition device 
which automatically lights burner.  DO NOT 
attempt to light the burners manually. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                            FIGURE 13 
5- Depress knob on gas valve; knob will snap to OFF
6- Wait five minutes to clear out any gas. If you then 
smell gas, STOP! Immediately call your gas 
supplier from a neighbor’s phone. Follow the gas 
supplier’s instructions. If you do not smell gas go 
to next step. 
7- Turn knob on gas valve 90° counterclockwise to 
ON
8- Close unit door. 
9- Turn on electrical power to unit.  
10- Set the thermostat to desired setting. 
11- The combustion air blower will start. The burners 
will light within 40 seconds. 
12- If unit does not light first time (gas line not fully 
purged) it will attempt up to two more ignitions 
before locking out. 
13- If lockout occurs, repeat steps 1 through 10. 
14- 
If appliance still will not operate, follow the 
instructions “To Turn Off Gas to Unit" and call 
your service technician or gas supplier.
ROBERTSHAW 2000DER GAS VALVE 
 
 
 
OFF
 
MANIFOLD PRESSURE  
ADJUSTMENT SCREW 
UNDER CAP 
GAS VALVE KNOB 
SHOWN IN OFF POSITION 
INLET 
PRESSURE
TAP  
 
MANIFOLD  
PRESSURE TAP