SCH Collectors Installation & Operation Manual
Installer – Read all instructions, including 
this manual before installing.  Perform 
steps in the order given.
Have your collector(s) serviced/inspected 
by a qualified service technician, at least 
annually.
Failure to comply with the above could 
result in severe personal injury, death or 
substantial property damage.
When calling or writing about the collector 
– Please have the collector model and 
serial number.
Any claims for damage or shortage in 
shipment must be filed immediately 
against the transportation company by the 
consignee.
Factory warranty (shipped with the 
collector) does not apply to collectors 
improperly installed or improperly 
operated.
 WARNING
 NOTICE
1  
Introduction 
(continued)
  
Before getting started on your installation be sure to carefully 
read the preparation instructions in this section.
•  You must comply with local 
 
regulations, laws and standards of the 
 
local governing authority.
•  The frame must be capable of 
 
withstanding the local snow and wind 
  loads and permit the correct 
  anchoring of the collectors in 
 
accordance with all applicable local 
 regulations.
•  The load bearing capacity of the 
 
roofing and the frame shall be specially 
 
checked or analyzed by a structural 
 engineer.
•  The number of mounting brackets 
 
specified by the Lochinvar/TiSun 
 
manuals and parts sheets is based on 
 
an average collector load bearing per 
  square foot. The maximum 
  permissible collector loading per 
 
square foot may be calculated from the 
 
number of mounting brackets, taking 
 
into consideration the permissible 
 
loading on the mounting brackets.  If a 
 
higher collector wind and snow loading 
 
(including snow sliding off the roof) 
 
per square foot is required, additional 
 
mounting brackets will have to be 
 
used.  Roof pitches in excess of 30° also 
 
represent increased loading; additional 
 
mounting brackets must also be used 
 
for this variant.
 
CAUTION
 
CAUTION
   
SCH Collectors Installation & Operation Manual
5
Lochinvar/TiSun Solar Thermal Collectors 
are not specifically designed for drain back 
installations.  Consult the factory if drain 
back utilization is necessary.
 
CAUTION
•  The mounting substructure must be 
 
capable of withstanding the local 
 
snow and wind loads and permit 
 
correct anchoring of the collectors.
•  To avoid damage to the collectors 
 
and mounting frames from snow 
 
sliding off the roof, additional snow 
 
guards must be placed in sufficient 
 
numbers around the collectors and 
 
above the collectors.
• 
The collectors must be linked with a 
 
lightning arrester system and/or the 
 
building’s ground system by a licensed 
 electrician.
• 
Hydraulic connection of the collectors 
 
must be performed according to 
 Lochinvar/TiSun 
specifications.
• 
The collector connections must not be 
 
damaged, soiled or misaligned.  Take care 
 
during transport, installation, and 
 
connection of the modules.  Do not 
 
remove the header protection caps at the 
 
top and bottom connections of the 
 
collector until just before installation.
• 
When connecting the modules to the 
 
riser, the Hydraulic Connection Kit 
 
(corrugated pipe) supplied must be 
 
installed.  Otherwise, the warranty is 
 invalidated.
• 
Always connect the collector outlet and 
 
inlet flow to each other diagonally, 
  please follow the connection 
 
example (see FIG. 1-1 on page 6).
• 
Do not twist the headers when screwing 
 
the connections together.  Hold threaded 
 
connection in the desired position and 
 
tighten clamping ring union nut to 
 torque.
• 
Roof penetrations for solar piping must 
 
be  adequately sealed against water ingress. 
•  Use only the original sensor well 
 supplied.
• 
Use only high temperature and glycol 
 
pipe sealing materials. 
All piping should be properly insulated to 
avoid freezing and/or burn potential.
 
CAUTION