OBSERVED PROBLEM
ODS/pilot lights but flame goes 
out  when  control  knob  is  re-
leased
One or both burners do not light 
after ODS/pilot is lit
Delayed ignition burner
Burner  backfiring  during  com-
bustion
Slight smoke or odor during initial 
operation
TROUBLESHOOTING
Continued 
POSSIBLE CAUSE
1. Control  knob  not  fully 
pressed in
2. Control knob not pressed in 
long enough
3. Equipment shutoff valve not 
fully open
4. Pilot  flame  not  touching 
thermocouple, which allows 
thermocouple to cool, caus-
ing pilot flame to go out. This 
problem could be caused by 
one or both of the following:
  A) Low gas pressure
  B) Dirty or partially clogged 
ODS/pilot 
5. Thermocouple  connection 
loose at control valve 
6. Thermocouple damaged
7. Control valve damaged
1. Inlet gas pressure is too low
2. Burner orifice(s) clogged
3. Mislocated crossover tube
4. Remote  selector  in  OFF 
position
5. Wire disconnected from gas 
control
1. Manifold  pressure  is  too 
low
2. Burner orifice clogged
1. Burner orifice is clogged or 
damaged
2. Damaged burner
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
3.  Residues from manufacturing 
processes and logs curing
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep 
control  knob  pressed  in  30 
seconds
3. Fully open equipment shutoff 
valve
4. A)  Contact  local  natural  or 
propane/LP gas company
  B)  Clean  ODS/pilot  (see 
Cleaning  and  Maintenance
page 23) or replace ODS/pilot 
assembly 
5. Hand tighten until snug, then 
tighten 1/4 turn more
6. Replace pilot assembly
7. Replace control valve
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner(s) (see Cleaning 
and Maintenance, page 23) or 
replace burner orifice(s)
3.  Contact qualified service person
4. Put  remote  selector  in  ON 
position
5. See Wiring Diagram, page 28
1. Contact local natural or pro-
pane/LP gas company
2. Clean  burner  (see  Cleaning 
and Maintenance, page 23) or 
replace burner orifice
1. Clean  burner  (see  Cleaning 
and Maintenance, page 23) or 
replace burner orifice
2. Replace damaged burner
3. Replace gas control
1. Check  burner  for  dirt  and 
debris. If found, clean burner 
(see  Cleaning  and  Mainte-
nance, page 23)
2. Replace gas control
3. Problem will stop after a few 
hours of operation