Desa CRN30 사용자 설명서

다운로드
페이지 32
www.desatech.com
107883-01H
16
LIGHTING 
INSTRUCTIONS
1.  STOP! Read the safety information, page 
15, column 2.
2.  Make sure equipment shutoff valve is fully 
open.
3.  Turn thermostat control knob clockwise 
 to the OFF position (see Figure 22).
4.  Wait five minutes to clear out any gas. Then 
smell for gas, including near the floor. If you 
smell gas, STOP! Follow “B” in the safety 
information, page 15, column 2. If you donʼt 
smell gas, go to the next step.
5.  Turn  thermostat  control  knob  counter-
clockwise 
 to the pilot position. Press 
in thermostat control knob for 5 seconds 
(see Figure 22). 
 
Note:
 You may be running this heater for 
the first time after hooking up to gas supply. 
If so, you may need to press in thermostat 
control knob for 30 seconds or more. This 
will allow air to bleed from the gas system.
• If thermostat control knob does not pop 
up when released, contact a qualified ser-
vice person or gas supplier for repairs.
6.  Keep thermostat control knob pressed in 
while pushing down and releasing the ig-
nitor button (see Figure 22). This will light 
pilot. If necessary, continue to press ignitor 
button until pilot lights. 
If pilot does not light
• turn thermostat control knob clockwise 
 to the OFF position
• repeat steps 5 and 6
If pilot does not stay lit after several tries
• refer to Troubleshooting, page 19
• contact a qualified service person or gas 
supplier 
  Until repairs are made, light pilot with 
match. To  light  pilot  with  match,  see 
Manual Lighting Procedure, page 17.
7.  Keep thermostat control knob pressed in 
for 30 seconds after lighting pilot. After 30 
seconds, release control knob.
 
Note: 
If  pilot  goes  out,  repeat  steps  3 
through 7. This heater has a safety interlock 
system. Wait one minute before lighting 
pilot again.
OPERATING HEATER
Continued
8.  Turn  thermostat  control  knob  counter-
clockwise 
 to the desired heating level. 
The main burner should light. Set control 
knob to any heat level between 1 and 5 (see 
Figure 24).
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
Figure 22 - Control Knob In The OFF 
Position (Piezo Ignitor Shown)
Figure 23 - Pilot
Figure 24 - Burner Patterns
Control 
Knob
CRP16T
CRN18T
CRP26T
CRN30T
Ignitor Electrode
Pilot Burner
Thermocouple
TO TURN OFF GAS 
TO APPLIANCE
Shutting Off Heater
1.  Turn thermostat control knob clockwise 
 to the OFF position.
2.  Turn off all electric power to the appliance 
if service is to be performed. 
Shutting Off Burner Only (pilot stays lit)
Turn thermostat control knob clockwise 
 
to the PILOT position.
OF
F  
  P
ILO
Control Knob
Ignitor Button