GAS CONNECTION
GAS CONNECTION
GAS CONNECTION
GAS CONNECTION
GAS CONNECTION
NOTICENOTICENOTICENOTICENOTICE
CAUTIONCAUTIONCAUTIONCAUTIONCAUTION
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT: Loosen the pipe adapter
on the flex tube before installing to the
system piping.
FIGURE 5. Gas Connection
FIGURE 5. Gas Connection
FIGURE 5. Gas Connection
FIGURE 5. Gas Connection
FIGURE 5. Gas Connection
CHECK GAS TYPE:
CHECK GAS TYPE:
CHECK GAS TYPE:
CHECK GAS TYPE:
CHECK GAS TYPE: The gas supply must be the same as stated on heater's rating plate. If the gas supply is
different, DO NOT INSTALL the heater. Contact your dealer for the correct model.
Connecting dir
Connecting dir
Connecting dir
Connecting dir
Connecting directl
ectl
ectl
ectl
ectly to an unr
y to an unr
y to an unr
y to an unr
y to an unre
ee
eegula
gula
gula
gula
gulated pr
ted pr
ted pr
ted pr
ted propane/LPG tank can cause an e
opane/LPG tank can cause an e
opane/LPG tank can cause an e
opane/LPG tank can cause an e
opane/LPG tank can cause an explosion.
xplosion.
xplosion.
xplosion.
xplosion.
A qualif
A qualif
A qualif
A qualif
A qualified g
ied g
ied g
ied g
ied gas a
as a
as a
as a
as appliance installer m
ppliance installer m
ppliance installer m
ppliance installer m
ppliance installer must connect the f
ust connect the f
ust connect the f
ust connect the f
ust connect the fir
ir
ir
ir
ire
ee
eeplace to the g
place to the g
place to the g
place to the g
place to the gas suppl
as suppl
as suppl
as suppl
as supply
y
y
y
y.....
Consult all local codes.
Consult all local codes.
Consult all local codes.
Consult all local codes.
Consult all local codes.
WWWWW
ARNINGARNINGARNINGARNINGARNING
Use new black iron or steel pipe only. Internally tinned copper tubing can be used in some areas
Use new black iron or steel pipe only. Internally tinned copper tubing can be used in some areas
Use new black iron or steel pipe only. Internally tinned copper tubing can be used in some areas
Use new black iron or steel pipe only. Internally tinned copper tubing can be used in some areas
Use new black iron or steel pipe only. Internally tinned copper tubing can be used in some areas
when permitted by local codes. Only use pipe of 1/2" or greater diameter to allow full gas
when permitted by local codes. Only use pipe of 1/2" or greater diameter to allow full gas
when permitted by local codes. Only use pipe of 1/2" or greater diameter to allow full gas
when permitted by local codes. Only use pipe of 1/2" or greater diameter to allow full gas
when permitted by local codes. Only use pipe of 1/2" or greater diameter to allow full gas
volume to heater. Excessive pressure loss will occur if the pipe is too small.
volume to heater. Excessive pressure loss will occur if the pipe is too small.
volume to heater. Excessive pressure loss will occur if the pipe is too small.
volume to heater. Excessive pressure loss will occur if the pipe is too small.
volume to heater. Excessive pressure loss will occur if the pipe is too small.
A manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must be installed
A manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must be installed
A manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must be installed
A manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must be installed
A manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must be installed
upstream of the heater (FIGURE 4).
upstream of the heater (FIGURE 4).
upstream of the heater (FIGURE 4).
upstream of the heater (FIGURE 4).
upstream of the heater (FIGURE 4).
A sediment trap must be installed upstream of the heater to prevent moisture and contaminants
A sediment trap must be installed upstream of the heater to prevent moisture and contaminants
A sediment trap must be installed upstream of the heater to prevent moisture and contaminants
A sediment trap must be installed upstream of the heater to prevent moisture and contaminants
A sediment trap must be installed upstream of the heater to prevent moisture and contaminants
from passing through the pipe to the heater controls and burners. Failure to do so could
from passing through the pipe to the heater controls and burners. Failure to do so could
from passing through the pipe to the heater controls and burners. Failure to do so could
from passing through the pipe to the heater controls and burners. Failure to do so could
from passing through the pipe to the heater controls and burners. Failure to do so could
prevent the heater from operating reliably (FIGURE 4).
prevent the heater from operating reliably (FIGURE 4).
prevent the heater from operating reliably (FIGURE 4).
prevent the heater from operating reliably (FIGURE 4).
prevent the heater from operating reliably (FIGURE 4).