Vanguard Heating VS30PR 사용자 설명서

다운로드
페이지 32
26
103448
18" Variable
24" Variable
30" Variable
Btu (Variable)
16,000/26,000
20,000/33,000
21,500/36,000
Type Gas
Propane Only
Propane Only
Propane Only
Ignition
Piezo
Piezo
Piezo
Pressure Manifold
7.9" W.C.
7.9" W.C.
7.9" W.C.
Inlet Gas
Pressure (in. of water)
Maximum
14"
14"
14"
Minimum*
11"
11"
11"
* For purpose of input adjustment
Shipping Weight
32 lbs.
34 lbs.
36 lbs.
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA
International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
SPECIFICATIONS
SERVICE HINTS
When gas pressure is too low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane (LP) gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane (LP) gas
supplier.
WIRING
DIAGRAM
Switch
White
On
Off
Auto
Red
Red
White
Thermopile
Gas Control 
TPTH
TH
TPTH TP