Profile A provides only an OFF delay of one (1) minute at
100% of the cooling demand airflow.
OFF
100% CFM
100% CFM
1 min
OFF
Profile B ramps up to full cooling demand airflow by first
stepping up to 50% of the full demand for 30 seconds.  The
motor then ramps to 100% of the required airflow.  A one (1)
minute OFF delay at 100% of the cooling airflow is provided.
50% CFM
1/2 min
100% CFM
100% CFM
1 min
OFF
OFF
Profile C ramps up to 85% of the full cooling demand airflow
and operates there for approximately 7 1/2 minutes.  The
motor then steps up to the full demand airflow. Profile C
also has a one (1) minute 100% OFF delay.
100% CFM
OFF
OFF
Profile D ramps up to 50% of the demand for 1/2 minute,
then ramps to 85% of the full cooling demand airflow and
operates there for approximately 7 1/2 minutes.  The motor
then steps up to the full demand airflow.  Profile D has a 1/
2 minute at 50% airflow OFF delay.
OFF
OFF
Model
Tap
Low
Stage
Cool
High 
Stage 
Cool
Low 
Stage
Heat
High 
Stage 
Heat
A
370
660
880
1220
B
540
860
970
1340
C
790
1150
1040
1460
D
980
1470
1120
1590
A
530
900
1110
1600
B
730
1100
1200
1710
C
930
1430
1270
1800
D
1220
1880
1330
1910
A
500
780
1220
1730
B
740
1070
1250
1770
C
920
1380
1300
1840
D
1160
1780
1310
1870
A
390
630
600
820
B
550
800
650
890
C
680
1000
690
950
D
800
1210
730
1030
A
540
830
1140
1600
B
750
1090
1190
1690
C
980
1460
1270
1800
D
1210
1800
1330
1890
A
510
790
1230
1810
B
710
1100
1260
1850
C
910
1410
1300
1890
D
1160
1830
1330
1940
A
510
790
1230
1810
B
710
1100
1260
1850
C
910
1410
1300
1890
D
1160
1830
1330
1940
*CVM960805DX*
*CVM960604CX*
*MVM961005DX*
*MVM960805CX*
*MVM960603BX*
GCVM961005DX*
*MVM961155DX*
Airflow Table
7. Select the heating speed for your model from the heating
speed chart in the Specification Sheet.  The “adjust” setting
(already established by the cooling speed selection)
determines which set of speeds are available.  The selected
speed must provide a temperature rise within the rise range
listed with the particular model.
8. Select the desired “heating” speed tap by positioning
switches 3 and 4 appropriately.  Refer to figure above. Verify
CFM by noting the number displayed on the dual 7-segment
LED display.
In general lower heating speeds will: reduce electrical consump-
tion, lower operating sound levels of the blower, and increase the
outlet air temperature delivered to the home.   The speeds avail-
able allow the blower performance to be optimized for the particu-
lar homeowner’s needs.