Submenu Item
Indication (for Display Only; not User Modifiable)
Number of  Heat Stages (HT STG)
Displays  the number  of furnace  heating stages
Input Rate (BTU/HR)
Displays the furnace input rate in kBtu/hr
Motor HP (1/2, ¾, or 1 MTR HP)
Displays the furnace indoor blower motor horsepower
CONFIGURATION
Submenu Item
Indication/User Modifiable Options
Comments
Fault  1  (FAULT #1)
Most  recent furnace fault
For display only
Fault  2  (FAULT #2)
Next most recent  furnace fault
For display only
Fault  3  (FAULT #3)
Next most recent  furnace fault
For display only
Fault  4  (FAULT #4)
Next most recent  furnace fault
For display only
Fault  5  (FAULT #5)
Next most recent  furnace fault
For display only
Fault  6  (FAULT #6)
Lease recent furnace  fault
For display only
Clear Fault History (CLEAR)
NO or YES
Selecting “YES” clears  the  fault 
history
NOTE: Consecutively repeated faults are shown a maximum of 3 times.
DIAGNOSTICS
Submenu Item
Indication (for Display Only; not User Modifiable)
Model  Number (MOD NUM)
Displays the furnace model  number
Serial  Number (SER NUM)
Displays the furnace serial number  (Optional)
Software (SOFTWARE)
Displays the application software revision
IDENTIFICATION
Submenu Item
User Modifiable Options
Comments
Heat Airflow Trim (HT TRM)
-15% to +15% in 3% increments, 
default is 0%
Trims the heating airflow by the selected 
amount.
Heat  ON Delay (HT ON
5, 10, 15, 20, 25, or 30 seconds, 
default is 30 seconds
Selects the indoor blower heat ON delay
Heat OFF Delay  (HT OFF)
30, 60, 90, 120, 150, or 180 seconds, 
default is 150 seconds
Selects the indoor blower heat OFF delay
Heat Airflow  (HT ADJ)
1, 2,  3, or 4
Selects the  nominal heating airflow (see 
Section XIV, Startup Procedure  and 
Adjustment – Circulator  Blower Speeds 
 for 
addition information)
SET-UP
Submenu  Item
Indication (for Display Only; not User M odifiable)
Mode (MODE)
Displays the current furnace operating  mode
CFM (CFM
Displays the airflow for the current operating mode
STATUS