Recommended Installation Positions
NOTE: Alternate “vertical” piping connections can not be used
when an upflow furnace is installed with supply air discharging to
the right, or when a counterflow furnace is installed with supply air
discharging to the left.  In either case, use the standard flue and
combustion air piping connections.
A
LTERNATE
 E
LECTRICAL
 
AND
 G
AS
 L
INE
 C
ONNECTIONS
This furnace has provisions allowing for electrical and gas line con-
nections through either side panel.  In horizontal applications the
connections can be made either through the “top” or “bottom” of
the furnace.
D
RAIN
 P
AN
A drain pan must be provided if the furnace is installed above a
conditioned area.  The drain pan must cover the entire area under
the furnace (and air conditioning coil if applicable).
F
REEZE
 P
ROTECTION
Refer to Horizontal Applications and Conditions - Drain Trap and
Lines.
P
ROPANE
 G
AS
/H
IGH
 A
LTITUDE
 I
NSTALLATIONS
WARNING
P
OSSIBLE
 
PROPERTY
 
DAMAGE
PERSONAL
 
INJURY
 
OR
 
DEATH
 
MAY
 
OCCUR
 
IF
 
THE
 
CORRECT
 
CONVERSION
 
KITS
 
ARE
 
NOT
 
INSTALLED
. T
HE
 
APPROPRIATE
 
KITS
 
MUST
 
BE
 
APPLIED
 
TO
 
ENSURE
 
SAFE
 
AND
 
PROPER
 
FURNACE
 
OPERATION
. A
LL
 
CONVERSIONS
 
MUST
 
BE
 
PERFORMED
 
BY
 
A
 
QUALIFIED
 
INSTALLER
 
OR
 
SERVICE
 
AGENCY
.
This furnace is shipped from the factory configured for natural gas
up to 10,000 ft. altitude.  Propane conversions require the proper
LP kit to compensate for the energy content difference be-
tween natural and propane gas.
LP kits include a manifold assembly, including an LP gas
valve, orifices and LP burners.
Hig h Stage
Low  Stage
Natural
None
#45
1
3.5" w.c.
1" w.c.
None
Propane
LPKMOD** ***
1.25MM
2
10.0" w.c .
2.6" w. c.
None
NO TE:   In  Canada,   gas  furnaces  are only  cert ified t o  4500  f eet.
O rifice
2
  Except 115,000  BT U: #55
1
  Except 115,000  BT U:   #43
Gas
0-7000
Manifo ld Pressure
Pr essure
Switch 
Change
Altitude
Ki t
GCVM961005DX
LPKMOD100CF
A/GCVM960604CX
LPKMOD060CF
A/GCVM960805DX
LPKMOD080CF
A/GMVM961005DX
A/GMVM961155DX
LPKMOD060UF
LPKMOD080UF
LPKMOD100UF
LPKMOD115UF
Furnace Model
LP Kit
A/GMVM960603BX
A/GMVM960805CX
The indicated kits must be used to insure safe and proper furnace
operation.  All conversions must be performed by a qualified in-
staller, or service agency.
V
ENT
/F
LUE
 P
IPE
 & C
OMBUSTION
 A
IR
 P
IPE
F
AILURE
 
TO
 
FOLLOW
 
THESE
 
INSTRUCTIONS
 
CAN
 
RESULT
 
IN
 
BODILY
 
INJURY
 
OR
 
DEATH
. C
AREFULLY
 
READ
 
AND
 
FOLLOW
 
ALL
 
INSTRUCTIONS
 
GIVEN
 
IN
 
THIS
 
SECTION
.
WARNING
U
PON
 
COMPLETION
 
OF
 
THE
 
FURNACE
 
INSTALLATION
CAREFULLY
 
INSPECT
 
THE
 
ENTIRE
 
FLUE
 
SYSTEM
 
BOTH
 
INSIDE
 
AND
 
OUTSIDE
 
OF
 
THE
 
FURNACE
 
TO
 
ASSURE
 
IT
 
IS
 
PROPERLY
 
SEALED
. L
EAKS
 
IN
 
THE
 
FLUE
 
SYSTEM
 
CAN
 
RESULT
 
IN
 
SERIOUS
 
PERSONAL
 
INJURY
 
OR
 
DEATH
 
DUE
 
TO
 
EXPOSURE
 
TO
 
FLUE
 
PRODUCTS
INCLUDING
 
CARBON
 
MONOXIDE
.
WARNING
A condensing gas furnace achieves its high level of efficiency by
extracting almost all of the heat from the products of combustion
and cooling them to the point where condensation takes place.
Because of the relatively low flue gas temperature and water con-
densation requirements, PVC pipe is used as venting material.
This furnace must not be connected to Type B, BW, or L vent or
vent connector, and must not be vented into any portion of a fac-
tory built or masonry chimney except when used as a pathway for
PVC as described later in this section.  Never common vent this
appliance with another appliance or use a vent which is used by a
solid fuel appliance.  Do not use commercially available “no hub
connectors” other than those shipped with this product.