 Operating the Controls - continued 
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Using Your Humidifier 
 
 
 
 
 
 
 
 
 
Speed Button 
 
This humidifier is equipped with a 
3-speed fan control. Initially depressing 
the speed button will display the current 
speed setting. Each push of the speed 
button advances the mode through the 
settings of (HIGH) F3, (MEDIUM) F2 and 
(LOW) F1
.  
The selected setting is displayed on the 
digital readout. The higher the setting, 
the faster water is evaporated and  
released into the air. F1 (LOW) is the 
quietest setting and is provided for 
conditions that do not require a rapid 
evaporation rate.  
Humidity Control 
 
This button allows you to adjust 
the humidity to suit your needs. 
This humidifier will automatically 
cycle on and off as required to 
maintain the selected setting. The 
readout displays both actual 
(ROOM) and desired (SET) 
humidity percentage (%) settings 
when humidity control button is 
pressed. The ROOM readout has 
a range of 20% to 95%. If the 
room humidity level is equal to or 
less than 20% the display will 
show a flashing 20. 
The SET readout has a range of 
25% to 65% and is adjusted in 
increments of 5%. Initially 
depressing the humidity button will 
display the current humidity 
setting. Each additional press of 
the button increases the setting by 
5%. A SET point of 65% operates 
the humidifier continuously 
regardless of the ROOM reading. 
The humidistat that senses the 
readings is located on the power 
cord. Insure that it is free from 
obstructions. 
Refill Display 
For maximum run time both the bottle 
and the base should be filled. When 
both the bottle and the base are empty 
the display alternates the room 
humidity reading and “F” (FILL), 
indicating that additional water is 
required. Also at this time the unit will 
automatically switch into DRY OUT 
MODE
 and continue to run on the 
lowest speed until the filter is dry. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOTE: During this time the room humidity level will continue to be monitored 
and the humidifier will cycle the fan on and off until the filter is completely dry. 
The fan will shut off leaving you with a dry humidifier that is less prone to mold 
and mildew growth. If DRY OUT MODE is not desired, refill the humidifier with 
water and the fan will return to the set speed. 
NOTE: Fan automatically switches to lowest speed during DRY OUT MODE. 
 
 
Humidistat 
The humidistat located on the power cord senses the percentage of humidity in 
the air. It causes the humidifier to cycle on and off to maintain the selected 
humidity SET point. The fan will turn on if the “ROOM” reading falls 3% below 
the SET point and will continue to run the humidifier until a reading of 1% above 
the SET point is achieved. The fan will turn off until the ROOM reading falls 3% 
below the SET point again. 
NOTE
: Be sure that the humidistat, which is located on the power cord, is free 
from obstruction and away from any hot air source. 
Check Filter Indicator 
The ability of any humidifier to 
efficiently supply humidity output 
relies heavily on the condition of the 
filter. As the filter loads with impurities 
it gradually loses its wicking capability. 
When this happens, moisture output is 
reduced and the humidifier has to 
work longer to satisfy the selected 
setting. This humidifier has a check 
filter reminder timed to appear after 
720 hours of operation. When display 
shows an alternating “CF” and “room 
humidity” setting at 5 second intervals 
it is a reminder to check the filter 
condition