Enerco TSVFB10LP 사용자 설명서

다운로드
페이지 16
3
Installation Instructions and Owner’s Manual
Unvented Liquid Propane Fired Room Heater
DANGER: Carbon monoxide poisoning may lead to 
death. 
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble the 
flu, with headaches, dizziness, or nausea. If you have 
these signs, the heater may not be working properly. 
Get fresh air at once! Have heater serviced. Some 
people are more affected by carbon monoxide than oth-
ers. These include pregnant women, persons with heart 
or lung disease or anemia, those under the influence of 
alcohol, and those at high altitudes.
Propane/LP Gas:
Propoane/LP gas is odorless. An odor making agent is 
added to propane/LP gas. The odor helps you detect 
a Propane/LP gas leak. However the odor added to 
propane/LP gas may be present even though no odor 
exists. Make certain you read and understand all warn-
ings. Keep this manual for reference. It is your guide to 
safe and proper operation of this heater.
Product Features
Figure 1
PRECAUTIONS:
1. BF-10 LP and IR-10LP may be installed in a bed-
room, but not a bathroom, or any place where a 
strong wind would shut down the appliance.
2. This heater needs outside ventilation air to run 
properly. The Oxygen Depletion Sensor (ODS) safety 
shutoff system shuts down the heater if not enough 
fresh air is available. See Fresh Air for Combustion 
and Ventilation, page 3.
3. Keep all air openings in heater clear, free of debris 
or any blockage. This will insure that enough air for 
proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide 
fresh, outside air. If heater keeps shutting off, it re-
quires servicing.
5. Turn off and let cool before servicing. Only a quali-
fied service person should service and repair heater.
6. Do not run heater:
•  Where flammable liquids or vapors are used or stored
•  During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner or 
similar products, turn heater off. If heated the vapors 
from these products may create a white powder 
residue within burner box or on adjacent walls or 
furniture.
8. Do not use heater if any part has been underwater. 
Immediately call a qualified service technician to in-
spect the room heater and to replace any part of the 
control system and any gas control which has been 
underwater.
9. Operating heater above elevations of 4,500 feet 
could cause pilot/ODS to shutdown heater.
10.Always run heater with control knob in a locked posi-
tion. Never set control knob between locked posi-
tions. Poor combustion and higher levels of carbon 
monoxide may result if control knob is left between 
locked positions.
Control Knob
Grill
Front Panel
Burners
Heater 
Cabinet
SPECIFICATIONS
IR10 LP 
BF10LP 
BTU (Available) 
10,000 
10,000 
Type of Gas 
LP-Gas Only 
LP-Gas Only 
Ignition 
Piezo 
Piezo 
Pressure Regulator Setting 
10 Inches of Water  
10 Inches of Water
Inlet Gas Pressure (Maximum) 
14 Inches of Water 
14 Inches of Water
Inlet Gas Pressure (Minimum) 
11 Inches of Water 
11 Inches of Water 
Burners / Orifice nozzles 
2  
1
Thermostatic Control 
No 
No
Clearances: inches (mm) 
 
 
  Top 
36” (915cm) 
36” (915cm) 
  Sides 
6” (152cm) 
6” (152cm) 
  Floor (min. to top of carpet) 
2” (51cm) 
2” (51cm) 
  Fabric / flammable objects 