Installation Instructions and Owner’s Manual
Unvented Liquid Propane Fired Room Heater
WARNING: A qualified service person must install 
heater. Follow all local codes. 
CHECK GAS TYPE
Use only LP-gas. If your gas supply is not LP-gas, do 
not install heater. Call dealer where you bought heater 
for proper type heater.
THIS INSTALLATION REQUIRES:
Before installing heater, make sure you have the items 
listed below:
Piping (check local codes)
Sealant (resistant to LP_Gas)
Equipment shutoff valve*
Ground joint union
Test gauge connection*
Sediment trap
Tee joint
Pipe wrench
*A CSA/AGA certified equipment shutoff valve with 1/8” 
NPT tap is an acceptable alternative to test gauge con-
nection. Purchase a CSA/AGA certified equipment shutoff 
valve from your dealer. 
LOCATING HEATER
This heater is designed to be mounted on the wall. The 
heater can also be located on a non-combustible floor, 
away from a wall by using the floor mounting stands in-
cluded with the heater. If installed on combustible floor-
ing such as carpeting, tile or other combustible material 
other than wood flooring, the heater must be placed on 
a wood panel the full width and depth of the appliance. 
Figure 4
For convenience and efficiency, install the heater:
Where there is easy access for operation, 
inspection, and service.
In the coldest part of the room.
CAUTION: If you install the heater in a home garage:
Heater pilot and burner must be at least 18 
inches above floor . 
Locate heater where moving vehicle will not hit it. 
CAUTION: This heater creates warm air currents. These 
currents move heat to wall surfaces next to heater. Install-
ing heater next to vinyl or cloth wall covering or operat-
ing heater where impurities (such as tobacco smoke, 
aromatic candles, cleaning fluids, oil or kerosene lamps, 
etc.) are present in the air may discolor walls. 
WARNING: Never install the heater: 
•  In a recreational vehicle .
Where curtains, furniture, clothing, or other 
flammable objects are less than 36 inches from 
the front, top, or sides of the heater. 
•  As a fireplace insert 
•  In high-traffic areas 
•  In windy or drafty areas 
WARNING: Heater must be mounted to maintain 
the minimum clearances shown in Figure 4. If pos-
sible, provide greater clearances from the floor, ceil-
ing, and joining walls. 
FASTENING HEATER TO WALL
Mounting Bracket
The mounting bracket in located on the back panel of 
heater (see figure 5). It has been taped there for ship-
ping. Remove mounting bracket from back panel.
Figure 5
Removing Front Panel of Heater 
1.  Remove three screws on bottom front of front 
panel.
2.  Pull bottom of front panel forward, then down 
(see figure 6)
Attaching Mounting Bracket to Wall
Use holes on each end of mounting bracket to attach 
bracket to wall. These holes are 16 inches apart. Attach 
mounting bracket to wall in one of two following ways.
Mounting 
Bracket
Left 
Side
Right 
Side
36” min. from 
ceiling
6” Min from 
adjoining 
walls
2” min. to top surface of carpet, tile 
or other combustible material
Floor