FMI CCL3924PTA/NTA 사용자 설명서

다운로드
페이지 32
www.fmiproducts.com
124971-01C
10
INSTALLATION
Continued
Noncombus-
tible Material 
Distance (A)
Requirements for Safe 
Installation
12" or more Noncombustible material 
okay.
Between 8" 
and 12"
24" Models: Install fireplace 
hood accessory (GA6050 or 
GA6053 see Accessories, 
page 30). 
18" Model: Noncombustible 
material okay.
Less than 8" Noncombustible material 
must be extended to at least 
8". See Between 8" and 12"
above. If you cannot extend 
material, you must operate 
heater with flue damper open.
MANTEL CLEARANCES
In addition to meeting noncombustible mate-
rial clearances, you must also meet required 
clearances  between  fireplace  opening  and 
mantel shelf. If you do not meet the clearances 
in Figure 6, page 11 you will need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between man-
tel shelf and top of fireplace opening, a hood 
is not required (see Figure 6, page 11).
Determining Minimum Mantel Clearance 
When Using a Hood
If minimum clearances in Figure 6 are not 
met, you must have a hood. When using a 
hood there are still certain minimum mantel 
clearances required. Follow minimum clear-
ances  shown  in  Figure  7,  page  11  when 
using hood.
Heat Resistant
Material 
(A)
Figure 5 - Heat Resistant Material (Slate, 
Marble, Tile, etc.) Above Fireplace
NOTICE: Manual control heaters 
may be used as a vented product. 
If so, you must always run heater 
with chimney flue damper open. 
If  running  heater  with  damper 
open, noncombustible material 
above  fireplace  opening  is  not 
needed. Go to Installing Damper 
Clamp Accessory for Vented 
Operation, page 12.
Minimum Noncombustible Material 
Clearances
If Not Using Mantel
Note: If using a mantel, proceed to If Using 
Mantel. If not using a mantel, follow the infor-
mation below.
You  must  have  noncombustible  material(s) 
above the fireplace opening. Noncombustible 
materials (such as slate, marble, tile, etc.) must 
be at least 1/2" thick. With sheet metal, you 
must have noncombustible material behind 
it. Noncombustible material must extend at 
least 8" up. If noncombustible material is less 
than 12", you must install the fireplace hood 
accessory (24" models only). See Figure 5 for 
minimum clearances.
If Using Mantel
You  must  have  noncombustible  material(s) 
above the fireplace opening. Noncombustible 
materials (such as slate, marble, tile, etc.) must 
be at least 1/2" thick. With sheet metal, you 
must have noncombustible material behind it. 
Noncombustible material must extend at least 
8" up. If noncombustible material is less than 
12", you must install the fireplace hood acces-
sory (24" models only). Even if noncombustible 
material is more than 12", you may need the 
hood accessory to deflect heat away from your 
mantel shelf. See Figure 5 and Figure 6 and 7 
on page 11 for minimum clearances.