cable or 
conduit entry
350mm min.
35mm
510mm
shelf
150mm min
8mm
350mm
280mm
Ø10mm
6mm
575mm
 
Fixing dimensions 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Procedure 
 
Release the front cover from the unit by undoing the two screws 
under the bottom edge.  
 
Carefully remove cover by pulling bottom-front forward, and 
then lift to release top from retaining slots. 
 
Mark screw fixing positions on wall in accordance with the 
dimensions shown on the diagram in Fig 2. The unit must be 
secured to the wall with four screws through the holes provided. 
The two upper holes are keyhole shaped to enable the two 
upper screws to be positioned first. The unit can then be hung 
on these screws while the two lower screws are positioned. 
Before finally tightening all four screws, ensure the unit is truly 
horizontal. 
 
Fit a 3 core 1.5 square millimetre flexible cord through the cable 
entry bush, connect wires to the appropriate terminals and 
tighten cable clamp. Alternatively the heater may be connected 
with conduit through the base after removing the knockout 
containing the cable entry bush (see Fig. 2). 
 
 
Wiring Diagram
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
      
 
 Fig. 3
 
 
 
 
 
 
 
 
 
 
 
Operation  
 
 
 
 
 
 
 
 
 
 
 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig. 4 -  
Controls & Control 
Panel Layout 
 
The Dimplex WFC 3NB and WFC 3NS have a total loading of 
3Kw. They are fitted with two control knobs and a pilot light. The 
air inlet is in the front panel, and the outlet on the underside. 
The upper knob operates a six-position switch, giving a choice 
of operating characteristics as follows : 
 
 
▬ 
Off
 
 
        
▬ 
1Kw of heat, low fan speed
 
        
 
2Kw of heat, medium fan speed
 
▬ 
3Kw of heat, high fan speed. 
 
    
▬ 
Fan only, low speed
 
▬ 
Fan only, high speed
.
 
 
The lower knob operates a thermostat which enables the 
temperature of the room to be regulated. 
 
The pilot light indicates when the appliance is connected to the 
electricity supply. 
 
Thermal Safety Cut-out 
 
In the event that the appliance overheats, the cut-out switches 
the heater off automatically. To bring the heater back into 
operation, remove the cause of overheating, then turn Off the 
electrical supply to the heater for a few minutes. When the 
heater has cooled sufficiently reconnect and switch On the 
heater. If the cut-out operates repeatedly, contact your supplier. 
 
To control the room temperature, set the mark on the 
thermostat knob to the required temperature on the visually 
graduated scale (see Fig. 4). The thermostat will monitor 
continuously the temperature of the air returning to the inlet 
grille, and the heater element(s) selected will achieve or 
maintain the chosen temperature level efficiently and 
economically. 
 
When running Fan only modes, rotate thermostat knob to ‘max.’ 
position to ensure continuous cool air 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
          Fig. 2