This manual must be followed exactly.
1)  Read  the  safety  issues  completely  before  installing  the  Rinnai  Water  Heater. 
2) This  water  heater  is  suitable  for  water  (potable)  heating  or  space  heating. 
-  The  piping  and  components  connected  to  the  Rinnai  Water  Heater  must  approved 
for  use  in  portable  water  systems.
-  Toxic  chemicals  such  as  those  used  for  boiler  water  treatment  are  NOT  to  be     
introduced  to  the  portable  water  used  for  space  heating.
-  The  Rinnai  Water  Heater,  if  it  will  be  used  as  a  potable  water  source,  must  not  be   
connected  to  a  system  that  was  previously  used  with  a  nonpotable   
 
 
water  heating  appliance.
-  When  the  system  requires  water  for  space  heating  at  temperatures  higher   
 
than  required  for  other  uses,  a  means  such  as  mixing  valve  shall  be  installed  to 
temper  the  water  for  other  uses  in  order  to  reduce  the  scald  hazard  potential.
3)  The  Rinnai  Water  Heater  is  not  suitable  for  use  in  pool  or  spa  applications
4)   This  unit  is  designed  to  be  installed  indoors  using  the  proper  vent  piping  to 
exhaust  by-products  of  combustion  to  the  outside  environment.    Contact  your 
dealer  or  Rinnai  for  proper  vent  kits.    DO  NOT  operate  this  unit  without  vent  piping 
connected.    Exhaust  gasses  must  be  expelled  outside  the  home. 
5)   Maintain  proper  space  around  the  unit  for  proper  servicing  and  operation. 
 
Minimum  clearances  from  combustible  materials  are  listed  below.   
 
 
 
    Top  of  Heater 
inches 
 
 
 
    Back  of  Heater 
inch 
 
 
 
    Front  of  Heater   
inches 
 
 
 
    Sides  of  Heater 
inches 
 
 
 
    Floor   
 
12 
inches 
 
 
 
    Vent/Air  Intake 
inches 
I N S TA L L E R ’ S  I N S TA L L AT I O N  I N S T R U C T I O N S
-Warnings- (Commercial Unit)
6)   Installer  must  install  a  Pressure  relief 
valve.  Pipe  pressure  relief  discharge 
to  a  drain  or  outside  environment  (See 
pressure  relief  valve  section).
7)  The  appliance  should  be  located  in  an  area  where  leakage  of  the  unit  or 
connections  will  not  result  in  damage  to  the  area  adjacent  to  the  appliance  or 
to  lower  floors  of  the  structure.    When  such  locations  cannot  be  avoided,  it  is 
recommended  that  a  suitable  drain  pan,  adequately  drained,  be  installed  under 