Dutchwest Natural Vent Gas Heater
30002008
The Dutchwest Natural Vent Room Heater, Model  Nos. 2467 
and 2468,  is a vented gas appliance listed to the ANSI standard 
Z21.88b-2001  and CSA-2.33b-2001 for Vented Room Heaters, 
and  CSA 2.17-M91, Gas-Fired Appliances For Use at High Al-
titudes.
The installation of the Dutchwest Natural Vent Room Heater 
must conform with local codes, or in the absence of local codes, 
with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edi-
tion and CSA B-149.1  Installation Code.  (EXCEPTION:  Do not 
derate this appliance for altitude.  Maintain the manifold pressure 
at 3.5 inches w.c. for Natural Gas and 10 inches w.c. for LP gas 
at maximum input.)    
This appliance is only for use with the type of gas indicated on 
the rating plate. This appliance is not convertible for use with other 
gases unless a certified kit is used. 
Installation and replacement of gas piping, gas utilization 
equipment or accessories, and repair and servicing of equip-
ment shall be performed only by a qualified agency.  The term 
“qualified agency” means any individual, firm, corporation, or 
company that either in person or through a representative is 
engaged in and is responsible for  (a) installation or replace-
ment of gas piping, or (b), the connection, installation, repair, 
or servicing of equipment, who is experienced in such work, 
familiar with all precautions required, and has complied with 
all the requirements of the authority having jurisdiction.
The  Dutchwest  Natural  Vent  Room  Heater  should  be 
inspected  before  use  and  at  least  annually  by  a  qualified 
service agency. It is imperative that control compartments, 
burners,  and  circulating  air  passageways  of  the  appliance 
be kept clean. 
The Dutchwest Natural Vent Room Heater and its individual 
shut-off valve must be disconnected from the gas supply piping 
during any pressure testing of that system at test pressures in 
excess of 1/2 psig (3.5 kPa).
The Dutchwest  Natural  Vent Room  Heater  must be isolated 
from the gas supply piping system by closing its individual manual 
shutoff valve during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 1/2 psig.
An  accessible  tap  is  located  above  the  pilot/on-off  knob  for 
checking the inlet pressure.
This appliance needs fresh air for safe operation and must be 
installed  so  there  are  provisions  for  adequate  combustion  and 
ventilation air. 
This  appliance  must  be  properly  connected  to  a  listed  4” 
(100mm) Type B venting system or to an approved masonry or 
factory-built  chimney  system.  In  Canada,  a  complete  reline  of 
Class A chimneys is required. This heater is equipped with a vent 
safety shutoff system.
This appliance must be properly connected to a venting 
system. WARNING: Operation of this heater when not con-
nected to a properly installed and maintained venting system 
or tampering with the vent safety shutoff system can result in 
carbon monoxide (CO) poisoning and possible death. 
This  appliance  is  approved  for  bedroom  installations  in  the 
U.S. and Canada.
This appliance may be installed in an aftermarket* manufactured 
(mobile) home, where not prohibited by state or local codes. 
The  Dutchwest  Natural  Vent  Room  Heater,  when  installed, 
must be electrically grounded in accordance with local codes or, 
in the absence of local codes, with the National Electrical Code 
ANSI/NFPA 70, (latest edition), or of the current Canadian Electri-
cal Code C22.1.
Due to high temperatures this appliance should be located 
out of traffic and away from furniture and draperies.
WARNING:  This appliance is hot while in operation.  Keep 
children, clothing, and furniture away.  Contact may cause 
burns or ignition of combustible materials.
Children and adults should be alerted to the hazards of high 
surface temperatures and should stay away to avoid burns or 
clothing ignition. Young children should be carefully super-
vised when they are in the same room as the appliance.
Clothing or other flammable materials should not be placed 
on or near the appliance. 
Any safety screen, glass or guard removed for servicing 
an appliance must be replaced prior to operating the appli-
ance.
The appliance area must be kept clear and free from com-
bustible  materials,  gasoline,  and  other  flammable  vapors 
and liquids.
The flow of combustion and ventilation air must not be ob-
structed. The installation must include adequate accessibility 
and clearance for servicing and proper operation.
WARNING:  Do not operate the Room Heater with the glass 
panel removed, cracked or broken. Replacement of the panel 
should be done by a licensed or qualified service person.
Do not use this appliance if any part has been under water. 
Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system and 
any gas control which has been under water.
Do not burn wood, trash or any other material for which 
this appliance was not designed. This appliance is designed 
to burn either natural gas or propane only.
This gas appliance must not be connected to a chimney 
flue serving a separate solid-fuel burning appliance.
CAUTION:  Label  all  wires  prior  to  disconnection  when 
servicing  controls.  Wiring  errors  can  cause  improper  and 
dangerous operation.
Verify proper operation after servicing.
* Aftermarket:   Completion of sale, nor for purpose of resale, 
from the manufacturer.
Installation & Operating Instructions
Proposition 65 Warning: Fuels used in gas, woodburning or oil 
fired appliances, and the products of combustion of such fuels, 
contain chemicals known to the State of  California to  cause 
cancer, birth defects and other reproductive harm.