1 Shielding for a top exit stove must include a shield insert to protect the area behind the flue collar.
2 Chimney connector heat shields must extend exactly 24” (610 mm) above the flue collar of the stove.
3 All installations venting straight up to a factory built chimney require a 24” (610 mm) diameter or square ceiling heat shield. The ceiling 
heat shield should be 24 gauge sheet metal or equivalent mounted on 1” (25 mm) non-combustible spacers 1” (25 mm) below ceiling.
4 Chimney connector heat shields must extend to within 1” (25 mm) or less of the ceiling heat shield for installations venting straight up to 
a factory-built chimney.  In top exit installations using an elbow to vent to the rear, the chimney connector must be shielded over the entire 
vertical length.
5 If a single-wall oval-to-round adaptor is used, a shield must be used to protect combustibles to the rear of the adaptor.
Stove and Chimney Connector Clearance Charts
  Stove Clearance 
Side 
Rear 
 Corner 
Side 
Rear 
Corner
No heat shields 
[A]  22” (560 mm)  [B]  24” (610 mm)  [C]  18” (460 mm)  [D] 12” (300 mm)  [E] 14” (360 mm)  [F] 10” (250 mm)
Rear exit, rear h.s. 
[G]  22” (560 mm)  [H]  14” (360 mm) 
N/A 
 [I]  12” (300 mm)  [J] 12” (300 mm) 
N/A 
Top exit
1
,  rear h.s.  
  Single-wall connector 
[K]  22” (560 mm)  [L]  24” (610 mm)  [M] 18” (460 mm)  [N]  12” (300 mm)  [O] 14” (360 mm)  [P] 10” (250 mm)
        
  No connector h.s.
Top exit
1,2  
, rear h.s.
  Single-wall connec- 
[K]  22” (560 mm)  [L] 14” (360 mm)  [M] 15” (380 mm)  [N]  12”(300 mm)  [O] 12” (360 mm)  [P] 8” (200 mm)           
  tor with connector h.s.                
 
 
Top exit
,  rear h.s. 
 
 Double-wall connector 
[K]  22” (560 mm)  [L] 19” (480 mm)  [M] 15” (380 mm)  [N]  12” (300 mm  [O]  11” (280 mm)  [P] 8” (200 mm)    
Chimney Connector Clearance:
Single-wall connector 
 
19” 480 mm)   
 
 
9” (230 mm)
   No connector h.s
Single-wall
 connector 
 
9” (360 mm)   
 
 
7” (180 mm)
   With connector h.s. 
 
Double-wall connector 
 
14” (360 mm)   
 
 
6” (150 mm) 
 
  
Front Clearance to Combustibles: 
 
48” (1220 mm) (All Installations)
 
 
Model 2460 Small Convection, and Model 2461 Large Convection:
         UNPROTECTED SURFACES 
 
      PROTECTED SURFACES
 
 
Corner 
 
Corner
 
Parallel Installations 
Installations 
Parallel Installations 
Installations
Model 2462 Extra-Large Convection:
  Stove Clearance 
Side 
Rear 
 Corner 
Side 
Rear 
Corner
No heat shields 
[A]  20” (510 mm)  [B]  23” (580 mm)  [C]  18” (460 mm)  [D]  18” (460 mm)  [E]  18” (460 mm) [F]  17” (430 mm)
Rear exit, rear h.s. 
[G]  20” (510 mm)  [H]  18” (460 mm) 
N/A 
[I]  18” (460 mm)  [J]  12” (300 mm) 
N/A
Top exit
1
,  rear h.s.  
  Single-wall connector 
[K]  20” (510 mm)  [L]  23” (580 mm)  [M]  18” (460 mm)  [N]  18” (460 mm)  [O]  18” (460 mm) [P]  17” (430 mm)
        
  No connector h.s.
Top exit
1,2  
, rear h.s.
  Single-wall connec- 
[K]  20” (510 mm)  [L]  18” (460 mm)  [M]  17” (430 mm)  [N]  18” (460 mm)  [O]  12” (300 mm) [P]  15” (380 mm)         
  tor with connector h.s.                
 
 
Top exit
,  rear h.s. 
 Double-wall connector 
[K]  20” (510 mm)  [L]  14” (360 mm)  [M]  16” (410 mm)  [N]  18” (460 mm)  [O]  12” (300 mm) [P]  15” (380 mm)
Chimney Connector Clearance:
Single-wall connector 
 
18” (460 mm)   
 
 
13” (330 mm)
   No connector h.s
Single-wall
 connector 
 
13” (330 mm)   
 
 
7” (180 mm)
3,4
   With connector h.s. 
 
Double-wall connector 
 
8” (200 mm)   
 
 
6” (150 mm) 
 
  
Front Clearance to Combustibles: 
 
48” (1220 mm) (All Installations)
 
 
         UNPROTECTED SURFACES 
 
      PROTECTED SURFACES
 
 
Corner 
 
Corner
 
Parallel Installations 
Installations 
Parallel Installations 
Installations