Thermo Products OD6FX072DV5R 사용자 설명서

다운로드
페이지 76
 
 28 
 
Heating Speed Set-ups  (Single Stage)  
 
 
Low Fire Med Fire High Fire
  
BTUH 
60,000 
72,000 
90,000 
 
Fan  
Control  
SW 1  
Switch  
Settings 
Heating 
CFM 
Approx. 
Rise (F
0
 )
Approx. 
Rise (F
0
 )
Approx. 
Rise (F
0
 )
Static 
Pressure 
in W.C.
Watts Amps 
0.2” 93 1.07 
3-OFF     
2-OFF     
1-OFF 
755 
73 
 
 
0.5” 162 1.80 
0.02” 109  1.25 
3-OFF     
2-OFF     
1-ON 
826 
66 
80 
 
0.5” 174 1.92 
0.02” 123  1.40 
3-OFF     
2-ON      
1-OFF 
898 
61 
74 
 
0.5” 203 2.20 
0.02” 146  1.63 
Factory 
SW1 Switch 
Settings 
3-OFF     
2-ON      
1-ON 
983 
56 
67 
84 
0.5” 226 2.45 
0.02” 176  1.95 
3-ON      
2-OFF     
1-OFF 
1068 
 
62 
77 
0.5” 259 2.78 
0.02” 204  2.23 
3-ON      
2-OFF     
1-ON 
1168 
 
57 
71 
0.5” 297 3.16 
0.02” 249  2.70 
3-ON      
2-ON      
1-OFF 
1282 
 
 
64 
0.5” 358 3.76 
0.02” 321  3.42 
3-ON      
2-ON      
1-ON 
1424 
  
  
58 
0.5” 455 4.73 
 
 
 
 
 
Figure 18-1:  ECM blower motor speed chart
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
= Recommended Heating Speed Setting