Thermo Products OD6FX072DV5R 사용자 설명서
32
M. BLOWER CONTROLLER INFORMATION FOR PSC MOTOR
(Note: for ECM blower controller information see: ECM Operation Manual document # Mo-440)
TERMINAL DEFINITIONS & FIELD WIRING
Burner Harness Connector P1
Pin 1- Limit switch connector.
Pin 2- 120 VAC Line connection.
Pin 3- Burner pilot contact.
Pin 4&5-
120 VAC Neutral connections.
Pin 6- Burner pilot contact.
Pin 7&8-
From oil primary control.
Pin 9- Limit Switch Input (LSI).
Field Wiring to Burner
Harness
Wires
Beckett Connections
Riello
Connections
Thermostat / Humidistat connections
“C”
“C”
Common
/
ground
“W”
Thermostat call for heat
“R”
24 VAC to thermostat
“G”
Thermostat call for fan
“Y”
Thermostat call for cool
“DEHUM”
Humidistat call for dehumidification (TXV systems ONLY)
Male quick connect terminals.
“S1-3”
“S1-3”
120
VAC
Hot
“N1-7”
120
VAC
Neutral
“EAC”
Electronic Air Cleaner (120 VAC) connection
“FAN”
Fan
On
Signal
“X”
24 VAC from transformer
“C”
24 VAC common from transformer
“CC”
Compressor
Contactor
“CC_COM”
Compressor Contactor Common
“LOW”
Continuous
Blower
Speed
“HEAT”
Blower heat speed tap
“COOL”
Blower cool speed tap
Pilot (Tstat) Neutral Line
Yellow Wires
White
Red
T-T terminals
White
Black
T-stat terminals
White
Black