N.  STARTUP PROCEDURES: 
A. Heating System 
1. Initial 
Startup: 
: Turn off power to furnace. Before the oil piping system is placed into service, it must 
have been leak tested by a qualified heating contractor.  
 
: For initial start-up of the appliance after installation, it may be necessary to purge the 
air out of the oil line. A qualified heating contractor should do this.  
 
Review the following items before the initial startup. It may be helpful to review the Sequence of 
Operations
 in Section VIII of this manual, also. 
 
 
a.  Check all wiring for loose connections and proper hook-up. Refer to the connection diagram. 
 
b.  Leak test all field oil piping connections. Generally, this will involve pressurizing the oil piping 
with air while being careful to isolate the oil tank at high test pressures.  A qualified heating 
contractor should perform this service.
 
 
c.  Check to see that the vent terminal is correctly installed and the terminal openings are clear 
and free from blockage.  
 
d.  Make sure the air filter is in place and relatively clean of dirt and debris. 
 
e.  Make sure the thermostat is set in the heating mode of operation. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Operating Instructions: 
i.  
STOP! Read the safety information above. 
ii.  
Set the thermostat to the lowest setting. 
iii.  
Turn off all electric power to the appliance. 
iv.  
This appliance is equipped with an ignition system that automatically lights the                                                          
burner. Do not try to light the burner by hand. 
v.  
Rotate the manual oil shutoff valve to the “ON” position. 
vi.  
Turn on the electric power to the appliance. 
vii.  
Set the thermostat to the desired setting.  
viii.  
If the appliance will not operate, call your qualified service technician or oil supplier. 
For Your Safety Read Before Operating: 
 
: If you do not follow these instructions exactly, a fire or 
explosion may result causing property damage, personal injury or loss of life. 
 
•  This appliance does not have a pilot light. It is equipped with an ignition system that 
automatically lights the burner. Do not attempt to light the burner by hand. 
  
• 
Do not use this appliance if any part has been under water. Immediately call a qualified 
service technician to inspect the appliance and to replace any part of the control system 
and any oil control that has been under water.