Cal Flame BBQ08899P 사용자 설명서

다운로드
페이지 28
Installation / 
Assemb
ly
9
Cal Flame Side Burners
LTR50001082, Rev. B
www.calspas.com
Natural Gas
Requirements
The  installation  of  this  appliance  must  conform  with  local  codes  or, 
in  the  absence  of  local  codes,  to  the  national  fuel  gas  code,  ANSI 
Z223.1a-1998. Installation in Canada must be in accordance with the 
standard CAN/CGA-B149.2, Propane Installation Code.
A licensed contractor or local gas company representative must per-
form all natural gas connections.
Ensure that the service supplying the side burner is fitted with a shut 
off valve conveniently positioned near the side burner and giving ease 
of access.
The side burner must be isolated from the gas supply piping system by 
closing its individual manual shutoff valve during any pressure testing 
of the gas supply piping system at test pressures equal to or less than 
0.5 psi (3.5 kPa).
The side burner and its individual shutoff valve must be disconnected 
from the gas supply piping system during any pressure testing of that 
system at test pressure in excess of 0.5 psi (3.5 kPa).
Connection
Slide the side burner forward to gain access to the gas connection 
1. 
point in the rear.
Connect a suitable flex connector to the gas connection point.
2. 
Check the side burner controls to ensure all control valves are in 
3. 
the full OFF position.
Turn on the main gas supply and check all connections for leaks 
4. 
using soapy water as described in the leak testing procedure sec-
tion.
Warning: If you see bubbles in the soapy solution at any of the connec-
tions, turn off the gas supply and tighten the connection. If tightening 
the connection does not seal the leak, it may be necessary to replace 
the flex hose.