INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools Needed
Tape measure
Small, flat-blade screwdriver
Flat-blade screwdriver
#2 and #3 Phillips screwdriver
Level
Wrench or pliers
Pipe wrench
Scissors or cutting pliers (to remove tiedowns)
Noncorrosive leak detection solution
Parts Needed
Gas line shutoff valve
½" male pipe thread nipple for connection to pressure 
regulator
LP gas-resistant pipe-joint compound
CSA design-certified outdoor flexible stainless steel 
appliance connector (4-5 ft [1.2-1.5 m]) or rigid gas supply 
line as needed.
Parts Supplied
Convertible regulator set for 4" WCP Natural gas.
Single-prong plug/5,000 mAmp transformer assembly
Location Requirements
Select a location that provides minimum exposure to wind and 
traffic paths. The location should be away from strong draft 
areas.
Do not obstruct flow of combustion and ventilation air.
Clearance to combustible construction for built-in outdoor sear 
burners:
A minimum of 24" (58 cm) must be maintained between the 
sides and back and any combustible construction.
A 24" (58 cm) minimum clearance must also be maintained 
below the cooking surface and any combustible construction.
Ignition
A grounded, 3-prong outdoor outlet located to the left of the sear 
burner is required. See “Electrical Requirements” section.
Product Dimensions
Built-In Outdoor Sear Burner Enclosure
The enclosure for the built-in outdoor sear burner is to be a 
minimum of 11" (28.0 cm) high x 23" (58.4 cm) deep x 
14" (35.6 cm) wide.
Cabinet Dimensions
Enclosure and clearance dimensions that are shown must be 
used. Given dimensions provide required clearances.
Counter or support surfaces must be level.
The installation of this sear burner must conform with local codes 
or, in the absence of local codes, with either the National Fuel 
Gas Code, ANSI Z223.1/NPFA 54, Natural Gas and Propane 
Installation Code, CSA B149.1, or Propane Storage and Handling 
Code, B149.2.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
A. 13" (33 cm)
B. 12
³⁄₄" (32.4 cm)
C. 17" (43.2 cm)
D. 26
³⁄₈" (67 cm)
E. 25
³⁄₈" (64.5 cm)
F. Manifold pipe
G. 2
¹⁄₂" (6.4 cm)
H. 22
³⁄₄" (57.8 cm)
B
A
D
E
F
G
H
B