Sterling SDA 1000-5100 사용자 설명서

다운로드
페이지 61
Large Dehumidifying Dryers 
Maintenance 
48 
 
1.  Access the desiccant canisters by removing the panels on the dryer. 
2.  Remove the Regeneration Heater Cover. 
3.  Unscrew the six (6) screws on the Heater Element Mounting Plate. 
4.  Slide out the heater assembly, taking care to not damage the gaskets. 
5.  Unscrew the heater loops that need to be replaced. 
6.  Re-install the new heaters. Securely tighten all fasteners. 
 
Caution! 
The heater loops should not touch each other. This will create "hot spots" 
and lead to premature heater failure. 
7.  Insert the heater assembly back into the desiccant canister. 
8.  Fasten the six (6) screws on the Heater Element Mounting Plate. 
9.  Re-secure the Regeneration Heater Cover.  
10. Re-install the dryer panels. 
  
 
 
 
Figure 20: Regeneration Heater Box Assembly 
Regeneration 
Heater Cover.
High 
Temperature 
Gaskets.
Heater Element 
Mounting Plate.
Access cover can be 
removed in order to 
replace desiccant.
Viewing Glass, for 
checking the status of 
the desiccant inside.
Regeneration 
Heaters
High 
Temperature 
Gaskets.
Stainless Steel 
Hollow Core 
Desiccant Tank
Desiccant Tank 
Mounting 
Platform