Therma-Stor Products Group Phoenix 200 HT 사용자 설명서

다운로드
페이지 9
2
www.thermastor.com • sales@thermastor.com
Toll-Free 1-800-533-7533
1 Specifications
Part No. 
4025900
Power 
7.5 amps, 0-20 VAC, Grounded
Water 
40 pints/day @ AHAM (80
°
F, 60%) 
Removal 
26 pints/day @ saturation 
 
32 gal/day maximum @ saturation
Blower 
325 CFM without external ducting 
 
30 CFM @ .5 IWG external static
 
Operating  
33°F min., 25°F max.
 
Range
Refrigerant    lbs., 4 oz. R-22 
Charge
 
Filters 
6” x 20” x 2” Pleated Media MERV-
Duct Options  Intake – 2” Flex-Duct 
 
Supply – 0” Lay-Flat 
Warranty 
Five years; 
 
st year 00% of Parts and Labor 
 
2nd–5th year 00% of Parts of sealed 
 
refrigeration system.
Dimensions
 
Machine  
Shipping
Width  
20.25”  
24” 
Height  
40”  
45.25” 
Depth  
2.375”  
25.5” 
Weight  
38 lb  
64 lb
2 Operation
2.1 Transporting
The Phoenix 200 HT must always be upright when 
transported by vehicle. It may be tipped onto its handle 
and back for loading and moving by hand. The Phoenix 
200 HT features a high-impact plastic skid plate which 
protects the unit while navigating obstacles such as curbs, 
stairways, and while loading into vehicles.
2.2 Electrical Requirements
The Phoenix 200 HT plugs into a common grounded outlet 
on a 5 Amp circuit. It draws 7.5 Amps at 80°F, 60% RH. 
If used in a wet area, a ground fault interrupter (GFI) is 
required. If an extension cord is required, it must have a 
minimum of 4 gauge conductors if 25 feet long or less 
and 2 gauge conductors if greater than 25 feet long.
Read the operation and maintenance instructions 
carefully before using this unit. Proper adherence to these 
instructions is essential to obtain maximum benefit from 
your Phoenix 200 HT dehumidifier.
• It is designed to be used INDOORS ONLY.
• If used in a wet area, plug it into a GROUND FAULT IN-
TERRUPTER.
• DO NOT use the Phoenix 200 HT as a bench or table.
• It must always be used in the upright position.
Table of Contents
Introduction ................................................................
1.   Specifications ........................................................2
2.   Operation .............................................................2
 
2. Transporting  ...................................................2
 
2.2 Electrical Requirements  ..................................2
 
2.3 Condensate Removal  ......................................2
 
2.4 Ducting ...........................................................2
 
2.5 Power Switch  .................................................3
 
2.6 Pump Purge Switch  .........................................3
 
2.7 Hour Meter  ....................................................3
 
2.8 Temperature Specific Operation  .......................3
 
2.9 Low Pressure Control  ......................................4
3.   Maintenance .........................................................4
 
3. Air Filter  .........................................................4
 
3.2 Storage  .........................................................4
4.   Service .................................................................
4
 
4. Technical description  ......................................5 
4.2 Troubleshooting  ..............................................5
 
4.3 Blower Replacement  .......................................6
 
4.4 Defrost Thermostat and Timer  .........................6
 
4.5 Condensate Pump  ..........................................6
 
4.6 Gravity Drain Option  ........................................6
 
4.7 Relay ..............................................................7
5.   Options and Accessories  .......................................7
6.   Wiring Diagram  ....................................................7
7.    Service Parts  .......................................................8
8.   Warranty
  ..............................................................9
Serial No. ___________________________
Purchase Date ______/______/_____
Dealer’s Name ___________________________________