English
   An airline Filter and In-Line Air Regulator adjustable to 120 PSI 
Max are required. (See Illustration)
   The NT50AGF Pneumatic Flooring Nailer requires Clean, Dry 
Air.  Use In-Line Regulator and Filter.  DO NOT USE IN-LINE 
OILERS WITH THE NT50AGF Pneumatic Flooring Nailer.  Dust, 
dirt and other particles in the system can cause premature 
wearing of the major components. Cylinder, piston, and O-
Rings are especially sensitive to wear caused by dirt or saw-
dust abrasion.
   Adjust the In-Line Air Regulator to 90-95 PSI. Be sure that the 
tool is not pointed at you or others when it is connected to the 
air supply source. NOTE: Some materials may require a higher 
pressure of 95-115 PSI in order to countersink the nail.  DO 
NOT EXCEED 120 PSI!
   NEVER use a defective tool. Replace worn or damaged parts 
immediately. Be sure that the Safety Trigger and operating 
mechanisms operate correctly and that all screws and seals are 
securely tightened at all times.
METHODS OF OPERATION
After connection with power source is made, check to be sure that 
the airline Regulator pressure is 90-115 PSI. Note: Some materi-
als may require a higher pressure in order to countersink the nail.  
Harder Material Flooring requires more pressure than typical Oak 
or Maple. Face Nailing requires approximately 5 PSI or more than 
Angle Nailing.
Ensure that tool is in proper working order and that there is no 
leaking of air.  If there is an air leak, Disconnect Immediately! Ar-
range for repairs by a Hitachi authorized service center.
After being sure tool is operable, place tool in position to be used.  
Always place the tool in proper position against the Flooring to be 
nailed before depressing the Trigger and striking the Ram.
Failure to use proper Air
Intake Filtration will result
in damage to both the Air
Compressor and the Tool.
Pressure Switch set to trip on at
115psi and to trip off a 135psi.
3/8” Air
Line
Air Line Filter
Drain Daily
Air Compressor
Accumulator
Tank
Condensate Drain Valve
Drain daily or more
frequently if needed
Air Valve
Air Line Regulator set at 95psi 
- Adjust upward as needed to 
110psi Max.
FLOORING
TOOL