Lifebreath 200MAX 사용자 설명서

다운로드
페이지 32
11
Model 200ERV
®
C L E A N   •   F R E S H   •   A I R
ENGINEERING DATA
LATENT RECOVERY/MOISTURE TRANSFER CORE
The cross-flow energy recovery core transfers heat and water
vapour between the two airstreams. It is easily removed for 
cleaning or service.
MOTORS AND BLOWERS
- Each air stream has one centrifugal
blower driven by a common PSC motor. 5 speed fan operation. 
High speed - 120 VAC, 182 Watts.
FILTERS
- Washable air filters in exhaust and supply air streams.
MOUNTING THE ERV
- Four threaded inserts at corners of case
designed to accept four PVC reinforced polyester straps that are
supplied with the unit.
CASE
- Twenty gauge prepainted galvanized steel (G60) for 
superior corrosion resistance. Insulated to prevent exterior 
condensation.
CONTROLS
- ControlAir 15
WEIGHT
63 lbs. (28.7 kg) 
SHIPPING WEIGHT
65 lbs. (29.6 kg)
PERFORMANCE 
Net supply airflow in cfm (L/s) against external static pressure
E.S.P
cfm
L/s
@ 0.1” (25 Pa)
214 
(101)
@ 0.2” (50 Pa)
206 
(97)
@ 0.3” (75 Pa)
193 
(91)
@ 0.4” (100 Pa)
184 
(87)
@ 0.5” (125 Pa)
170 
(80)
Sensible Effectiveness 
@127cfm (60 L/s) 
(CSA C439M)
67%
Sensible Efficiency    32°F (0°C)
60%
Total Efficiency 
55%
VAC @ 60HZ
120
WATTS / Low speed
70
STALE AIR
TO OUTSIDE
FRESH AIR
FROM OUTSIDE
STALE AIR
FROM INSIDE
FRESH AIR
TO INSIDE
14 
3
/
4
"
(375)
19"
(483)
DIMENSIONS 200ERV
 
 
inches (mm)
*
All Duct Connections 6"(150mm)
FILTERS
BLOWERS
*NOTE: Front clearance 
 of 25 inches (635 mm)  
 is recommended 
 for servicing unit. 
MOTOR
ENTHALPIC CORE
31"
(787)
BALANCING
DAMPER
OPTIONS
99-104    
Digital Electronic Timer
- 20/40/60 min. (3 wire)
99-105    
Deluxe Programmable Control
includes 
Programmable Time Clock, Dehumidistat 
and Air Sentry™
99-109    
Air Sentry
™ Air Quality Monitor designed to 
accept remotely mounted Control Pad
99-186   
Weatherhoods
, Two - 6” (150mm) 
c/w 1/4” (6mm) mesh screen
WARRANTY
Units carry a 5 year warranty on the energy recovery core and 
replacement parts.
All units conform to CSA and UL standards.
ERVs are not recommended for regions where the
design temperature is below 25°F (-4°C)
TI-98E
0202
DATE: __________________________
PROJECT: __________________________________________
MECHANICAL CONTRACTOR: _____________________________
511 McCormick Blvd.
London, Ontario  
N5W 4C8
Ph: (519) 457-1904
Fx: (519) 457-1676
Email:  nutech@lifebreath.com