NVB Series B-Vent Gas Fireplace
7412950
FP567
Fig. 13 Venting configurations.
�����
����������������������
��������
Venting Runs 
��
��
��
��
��
��
��
��
��
��
��
��
��
��
��
������������
��������������������������������
Horizontal Run (in feet)
Vertical Run (in feet)
A
A: Vertical installations up to 40 feet (12m) in 
     height. Up to a 6 ft. horizontal vent run can be
     installed within the vent system using a 
     maximum of two 90-degree elbows or four 
     45-degree elbows.
B: Vertical installations up to 40 feet (12m) in 
     height. Up to a 10 ft. horizontal vent run can be
     installed within the vent system using a 
     maximum of two 45-degree elbows. 
B
= Acceptable venting configuration
= Unacceptable venting configuration
FP567a
Fig. 14  Venting configurations when installing 36GSKBB.
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
2
4 6
8 10 12 14 16 18 20
A
FP567a
Venting Run 
Graph
8/17/99  djt
Horizontal Run (in feet)
Vertical Run (in feet)
= Acceptable venting configuration
= Unacceptable venting configuration
A: Vertical installation up to 40 feet (12m) in
    height. Up to a 16 ft. horizontal vent run
    can be installed within the vent system
    using a maximum of two 90 degree elbows 
    or four 45 degree elbows.
B: Vertical installation up to 40 feet (12m) in
    height. Up to a 20 ft. horizontal vent run 
    can be installed within the vent system
    using a maximum of two 45 degree elbows.
B