Vermont Casting NVBR36 사용자 설명서

다운로드
페이지 24
19
NVB Series B-Vent Gas Fireplace
7412950
In order to properly clean the burner and pilot assem-
bly, turn off the gas to the unit, open the glass door 
(if used), remove logs exposing the burner and pilot 
assembly. Clean all foreign materials from the top of the 
burner. Check to make sure that burner parts are clean. 
Visually inspect pilot. Brush or blow away any dust or 
lint accumulation If pilot orifice is plugged, disassembly 
may be required to remove any foreign material from 
the orifice or tubing.
To obtain proper operation, it is imperative that the pilot 
and burner's flame characteristics are steady, not lifting 
or floating.
Typically, the top 3/8" or 1/2" of the thermopile should 
be engulfed in the pilot flame. (Fig. 21)
To adjust pilot burner, turn pilot screw marked "pilot" for 
proper flame size.
The air shutter is set at factory no adjustment should be 
necessary.
Cleaning Electronic Ignition System
The Electronic Ignition burner/control system consists 
of:
• main burner 
• gas orifice
• pilot burner
• 24VAC valve with transformer
Taking care of the Electronic Ignition units is almost 
identical to taking care of the Standing Pilot models. 
Maintenance
Burner and Burner Compartment
It is important to keep the burner and the burner 
compartment clean. At least once per year the logs and 
lava rock/ember material should be removed and the 
burner compartment vacuumed and wiped out. Remove 
and replace the logs as per the instructions in this 
manual.
Always handle the logs with care as they are fragile 
and may also be hot if the fireplace has been in  
use.
FK12 Fan Assembly
The fan unit requires periodic cleaning. At least once 
per month in the operating season, open the lower 
louvre panels and wipe or vacuum the area around the 
fan to remove any build up of dust or lint.
Brass Trim 
Clean the brass trim pieces using a soft cloth lightly 
dampened with lemon oil. Do not use water or 
household cleaners on any brass components.
Contact your local representative to arrange an annual 
service program.
Cleaning the Standing Pilot 
Control System
The burner and control system consists of:
• main burner 
• gas orifice
• pilot burner
• thermopile
• combination millivolt gas valve
Most of these components may require only an occa-
sional checkup and cleaning and some may require ad-
justment. If repair is necessary, it should be performed 
by a qualified technician.