NVB Series B-Vent Gas Fireplace
7412950
Optional Accessories
Fan Kit
The FK12 fan kit is available for use on the NVBC36 
and NBVC42 model appliances only.
Auxiliary fan systems increase the efficiency of the cir-
culation of the heating air. The FK12 fan assembly is a 
fixed speed fan system and does not allow for variable 
speed control.
Installation
Remove the 2 ceramic fiber refractory panels by care-
fully lifting them out of the fireplace. Next, remove the 
access panel by  pulling it up and out from the side 
edge of the panel. Use caution — the panel edges may 
be sharp.
Center the fan assembly over the mounting location 
and secure it with the Velcro
®
 strips at the back of the 
fireplace.
Insert the plug into the receptacle (EB1) located against 
the lower right side wall of the fireplace.  
Caution: Be sure that no wires are pinched.
Prior to reinstalling the access panel and the hearth 
brick, it is advisable to operate the wall switch on and 
off to assure fan operation.  If the fan does not operate 
and you are assured that 115 VAC power is present at 
the receptacle, contact your Dealer.
Reinstall the access panel and hearth brick by reversing 
Step 1.
WARNING: Never contact blower wheels during 
operation. 
Speed Control
The SCVS variable speed control is available to allow 
speed adjustment of the fan.
Electrical Connection
The EB-1 electrical junction box is available for use with 
the fan kits. The EB-1 is standard on the electronic igni-
tion models.
Glass Doors
Bi-fold and single panel glass doors are available to 
enhance the viewing of the fireplace.
 
Appliance Models 
Glass Doors
 
NVBR36/NVBC36 
36GSKBB
 
 
36GDKBB
 
 
36GDKBK
 
 
36GDKDP
 
 
36GDKS
 
Appliance Models 
Glass Doors 
 
NVBR42/NVBC42 
42GSKBB
 
 
42GDKBB
 
 
42GDKBK
 
 
42GDKDP
 
 
42GDKS
Outside Air Kit
The Model AK-MST Outside Air Kit is designed to bring 
additional combustion air directly from the outside to the 
fireplace. Refer to installation instructions provided with 
the Outside Air Kit. 
Thermal Vent Damper
Installing the TVD6/7 Thermal Vent Damper reduces 
cold air infiltration when fireplace is not in use by open-
ing and closing automatically. 
Attach the  thermal vent damper to the combustion 
dome with 2 screws. Be sure the tab points down. (Fig. 
21) 
Start the appliance and operate it for approximately 5 
minutes. Turn the unit off and check if the vent damper 
is in the open position (blades down from the horizontal 
position). If the damper has not opened, check installa-
tion.
FP577
NVB—TVD6/7
11/17/97
Fig. 21  Attach the thermal vent damper.
FP577
Tab
Thermal Vent Damper
Screws
Remote Controls
Optional remote control units are available to control 
different functions of the appliance.
 
Model 
 
Function/s Controlled
 
RC1 
“ON/OFF”
 
RC2 
“ON/OFF” and Temperature
 
MRC3 
“ON/OFF” and Temperature control  
 
 
with a digital and a programmable 24  
 
 
hour clock
Shrouds
Decorative shrouds are available to enhance the ap-
pearance of the termination cap.
 
Square Shroud 
SLSBL