Vermont Casting NVBR36 사용자 설명서

다운로드
페이지 24
8
NVB Series B-Vent Gas Fireplace
7412950
WF597
NVC (from FP528)
12/2/97
Parts Identification and Chase Installation 
Fig. 7  Parts identification and system installation.
(Insulation methods shown are optional for cold climate, 
not a requirement for unit operation.)
FP597
*Do not install header 
until unit is in place. 
See Page 8, "Mounting 
the Appliance." 
Gas Line Installation
This appliance must be isolated from the gas supply 
piping system by closing its individual manual shut off 
valve during any pressure equal to or less than 1/2 psig 
(3.45 kPa).
The appliance and its individual shutoff valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of 1/2 psig (3.45 kPa).
If gas piping from the source to the appliance location 
has not been accomplished, install the required pipe. 
Consult local plumbing code to assure proper pipe size.
The gas pipeline can be brought in through the right 
side of the appliance. A knockout is provided  to al-
low for the gas pipe installation and testing of any gas 
connection.  It is most convenient to bring the gas line 
in from the right side, as this allows fan installation or 
removal without disconnecting the gas line.
NOTE: The gas line connection can be made with 3/8" 
copper tubing approved for propane or natural gas, 1/2" 
rigid pipe or an approved flex connector, then reduced 
to 3/8" to the appliance. Because some municipalities 
have some additional local codes, it is always best to 
consult your local authority. 
Batt Insulation
(cut out around 
firestop)
Firestop
Ceiling Level
Nailing Flange
Electrical Access
Outside Air Cover Plate
Termination Cap
Storm Collar
Pan Flashing
Draftstop
Standoff
Surround
Screen
Grate
Firebox