Vermont Casting TBREF36 사용자 설명서

다운로드
페이지 16
10007572
TBREF Electric Fireplace
5
Mantels
The height that a combustible mantel is fitted above the 
fireplace is dependent on the depth of the mantel. This 
also applies to the distance between the mantel leg (if 
fitted) and the fireplace.
For correct mounting height and width, refer to Figure 
2a and 2b.
The distances and reference points are not affected by 
the fitting of a bay window front trim kit.
Noncombustible mantels and legs may be installed at 
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such 
paint or lacquer must be heat-resistant to prevent dis-
coloration.
J
F
G
H
I
CFM164a
Mantel Leg Chart
06/22/01   sta
Black 
Surround 
Face
CFM164a
CFM170
DV Builder Front 
View
O
N
M
L
K
Side of Combustion 
Chamber
CFM170
Fig. 2b  Combustible mantel leg minimum installation.
 
 
Mantel 
 
Mantel Leg from Side
  Ref. 
Leg Depth 
Ref. 
of Comb. Opening
 
14"  (356mm) 
14"  (356mm)
 
12"  (305mm) 
12"  (305mm)
 
10"  (254mm) 
10"  (254mm)
 
8"  (203mm) 
8"  (203mm)
 
1¹⁄₂"  (38mm) 
1¹⁄₂"  (38mm)
Framing
1.  Choose fireplace location.
2.  Place fireplace into position.
3.  Frame in the fireplace with a header across the top. 
It is important to allow for finished face when setting 
the depth of the frame.
Four (4) nailing flanges are supplied with the fireplace 
(found on the fireplace hearth). To level the box and 
secure it firmly in place, remove the nailing flanges from 
the hearth and install at the sides of the fireplace as 
shown in Figure 3.
A B C D E
V
W
X
Y
Z
CFM146c
Electric Mantel 
Chart
1/22/04  djt
   
Mantel Shelf 
 
Mantel from Top       
  Ref. 
Depth 
Ref.  of Comb. Chamber
  V 
14"  (356mm) 
25"  (635mm) 
  W 
12"  (305mm) 
23"  (584mm) 
  X 
10"  (254mm) 
21"  (533mm) 
  Y 
8"  (203mm) 
19"  (483mm) 
  Z 
1¹⁄₂"  (38mm) 
15"  (381mm) 
Wall
Top of Combustion Chamber
CFM146b
Fig. 2a   Combustible mantel minimum installation.
Mantel Clearances
Mantel Leg