WinterWarm Fireplace Insert or System
2000941
10.  Install and Adjust the Controls.
The rods that operate the WinterWarm’s primary air, 
fan, and damper should be installed before mounting 
the column capitals and mantel. Two of the rods are    
1/4” (6mm) and are controls for the fan and the primary 
air. The third rod is 3/8” (9mm) and controls the damper. 
Install the rods by following this procedure: (Fig. 56)
• 
Check for proper position of the hex nuts on the 
threaded rods. The larger hex nut on the 3/8” (9mm) 
diameter rod should be positioned all the way to the 
end of the thread on the longer of the two threaded 
ends. The two smaller hex nuts on the 1/4” (6mm) 
rods should be positioned as follows:  One should 
be positioned as far up the thread as possible; the 
other should stop approximately 1/2” (13mm) from 
the end.  
• 
Install the fan control rod by inserting the 1/4” (6 
mm) diameter rod with the nut all the way at the end 
of the thread into the bottom control lever on the 
WinterWarm’s left side. Install the rod all the way up 
to the nut.  
• 
Tighten the hex nut against the lever.
• 
Thread the two remaining control rods into the re-
maining two control levers. The lever above the fan 
control accepts the remaining 1/4” (6mm) rod; this is 
the primary air control. The lever on the right side of 
the WinterWarm accepts the 3/8” (9mm) rod; this is 
the damper control.
When installing the damper rod, look from above at the 
damper linkage. Note that the linkage should be flexed 
towards the rear.  Make sure the linkage is in this orien-
tation.  The damper will not operated properly with the 
linkage flexed to the front.
  Thread each rod into the lever until it reaches the nut.
  Tighten the two hex nuts against the levers. The pri-
mary air and fan controls will be offset 1/2” (13mm) 
to allow for smooth adjustment.
11.  Install the Air Divider.
Install the two vertical 
sheet metal air dividers 
which guide the incoming 
and outgoing convection 
air. (Fig. 57) They are not 
interchangeable:  the curved 
flange goes downward and 
faces the firebox. The two 
punchouts go toward the 
front.  
Angle the front edge into 
position in the notch at the 
top of the column, while 
guiding the curved flange at 
the bottom so that it slides in 
on top of the curved horizon-
tal flange that is cast into the 
firebox side.
The top edge of the air 
FP1133
controls
7/2/01   djt
Blind-Tapped Hole
Control Lever
Brass 
Knob
1/2” (13mm)
Through-Tapped Hole
L-Bracket
FP1133
Fig. 56  Adjsut the controls so the primary air control rod, on 
the top, overhangs the fan control rod by 1/2” (13mm)
divider must be flush with the top of the boss in the cast 
column, as shown in the circled area in Figure 58.
Push the rear edge in until the air divider is perpendicu-
lar to the column.
FP1135
air divider
top view
7/01
Cast Winter-
Warm Flange
Air Divider 
Flange
2. Adjust 
Bottom 
Here
Boss
Notch
1. Seat Here
3. Push in 
Here
FP1135
Fig. 58   1. Seat entire length of air divider in notch. 2. Adjust 
the seated air divider so its bottom flange is just above cast 
flange of WinterWarm. 3. Push the opposite side of the air 
divider so it snaps into place.
FP1134
air divider
7/01
FP1134
Fig. 57  Seat the entire 
length of the air divider 
in the notch between the 
bosses shown here as a 
dotted line.
Air 
Divider